10. Click Accept to accept the confi guration of the new virtual disk.
Note: Click the Reclaim button if you want to undo a virtual disk that you just
defi ned.
11. Click Next to continue with the next confi guration step. The Virtual Disk Sum-
mary window appears.
12. Review the confi guration shown in the window. If you want to change something,
click Back and change the confi guration parameters.
13. Click Finish to accept the confi guration and start the initialization process (un-
less you selected No Initialization earlier).
Using Manual Confi guration: RAID 50
Follow these steps to create a RAID 50 storage confi guration using the Manual
Confi guration mode of the Confi guration Wizard:
1. In the fi rst Manual Confi guration window, shown in Figure 6-5, select two avail-
able drives in the left panel. Click the Right Arrow button to move the selected
drives to the right panel.
2. Click Accept to accept these drives for a new RAID 5 array.
3. Select two more drives for a second RAID 5 array, and click Accept.
4. To add a hotspare, select an available drive in the left panel. Select the array from
the drop-down menu, and click Add Hotspare To , as shown in Figure 6-7.
5. To remove a hotspare from an array, select it in the right panel and click Remove
HotSpare.
6. Click Next.
The next Confi guration Wizard window appears, as shown in Figure 6-6.
The Arrays with Free Space menu lists the new arrays that you just defi ned,
plus any existing arrays with holes (free space) that could be used for a new
confi guration.
7. In the left panel, select the two RAID 5 arrays from the menu.
8. In the right panel, select RAID 50 as the RAID level.