2-8
A+ SERVER 2022TC-BIBQRF/BTRF User's Manual
2-5 Checking the Serverboard Setup
After you install the 2022TC-BIBQRF/BTRF in the rack, you will need to open the
unit to make sure the serverboard is properly installed and all the connections
have been made.
Accessing the inside of the System
Before operating the server for the fi rst time, it is important to remove the protective
fi lm covering the top of the chassis, in order to allow for proper ventilation and
cooling.
Removing the Chassis Cover and Protective Film
Remove the two screws which secure the top cover onto the chassis as 1.
shown above.
Lift the top cover up and off the chassis.2.
Peel off the protective fi lm covering the top cover and the top of the chassis3.
Check that all ventilation openings on the top cover and the top of the chassis 4.
are clear and unobstructed.
Checking the Components and Setup
You may have one or two processors already installed into the serverboard. 1.
Each processor needs its own heat sink. See Chapter 5 for instructions on
processor and heat sink installation.
Your 2022TC-BIBQRF/BTRF server system may have come with system 2.
memory already installed. Make sure all DIMMs are fully seated in their slots.
For details on adding system memory, refer to Chapter 5.
If desired, you can install add-on cards to the system. See Chapter 5 for 3.
details on installing PCI add-on cards.
Make sure all power and data cables are properly connected and not blocking 4.
the chassis airfl ow. Also make sure that no cables are positioned in front of
the fans. See Chapter 5 for details on cable connections.