3-2
AS2041M-32R+/2041M-T2R+ User's Manual
3-3 Control Panel LEDs
The control panel located on the front of th SC815TQ-560C chassis has fi ve LEDs.
These LEDs provide you with critical information related to different parts of the
system. This section explains what each LED indicates when illuminated and any
corrective action you may need to take.
Overheat/Fan Fail
When this LED fl ashes it indicates a fan failure. When on continuously (on and
not ashing) it indicates an overheat condition, which may be caused by cables
obstructing the air ow in the system or the ambient room temperature being too
warm. Check the routing of the cables and make sure all fans are present and
operating normally. You should also check to make sure that the chassis covers
are installed. Finally, verify that the heatsinks are installed properly (see Chapter
5). This LED will remain fl ashing or on as long as the overheat condition exists.
NIC2
Indicates network activity on JLAN2 when fl ashing .
NIC1
Indicates network activity on JLAN1 when fl ashing.
HDD
Indicates IDE channel activity. On the 2041M-32R+/2041M-T2R+ this light indi-
cates SAS/SATA and/or DVD-ROM drive activity when fl ashing.