SUPERSUPERSERVER 6016T-MTUSER’S MANUALRevision 1.0a®
NotesxSUPERSERVER 6016T-MT User's Manual
C-2SUPERSERVER 6016T-MT User's ManualWeight Gross Weight: 38 lbs. (17.3 kg.)System Cooling Four 4-cm high-performance fansSystem Inp
C-3Appendix C: System Specifi cationsNotes
C-4SUPERSERVER 6016T-MT User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life supp
Chapter 1 Introduction1-1 OverviewThe SuperServer 6016T-MT is a 1U rackmount server designed for optimal space effi ciency and comprised of two main su
1-2SUPERSERVER 6016T-MT User's Manual1-2 Serverboard FeaturesThe X8DTL-i is a dual processor serverboard based upon Intel's 5500 + ICH10R ch
Chapter 1: Introduction1-3Figure 1-1 . Intel 5500 Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapter 5 for detail
1-4SUPERSERVER 6016T-MT User's Manual1-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC813MTQ-520CB ch
Chapter 1: Introduction1-51-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (40
1-6SUPERSERVER 6016T-MT User's ManualNotes
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 6016T-
2-2SUPERSERVER 6016T-MT User's Manual!!Warnings and Precautions!installation only in a Restricted Access Location (dedicated equipment rooms, ser
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
Manual Revision 1.0a Release Date: December 22, 2009The information in this User’s Manual has been carefully reviewed and is believed to be accu
2-4SUPERSERVER 6016T-MT User's Manual2-4 Installing the System into a RackThis section provides information on installing the SuperServer 6016T-
Chapter 2: Server Installation2-5Installing the Rack RailsDetermine where you want to place the SuperServer 6016T-MT in the rack (see Rack and Server
2-6SUPERSERVER 6016T-MT User's ManualFigure 2-2. Installing the Server into a Rack (with optional front bezel shown)Installing the Server into t
Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a Telco Rack (with optional front bezel shown)Installing the Server into a Te
2-8SUPERSERVER 6016T-MT User's Manual2-5 Checking the Motherboard SetupAfter you install the 6016T-MT in the rack, you will need to open the uni
Chapter 2: Server Installation2-92-6 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives and the SATA drives and th
2-10SUPERSERVER 6016T-MT User's ManualNotes
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SATA drive ca
3-2SUPERSERVER 6016T-MT User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC813MTQ-520CB chassis has fi ve LEDs. T
Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated
PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an
3-4SUPERSERVER 6016T-MT User's ManualNotes
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
SUPERSERVER 6016T-MT User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area around the 6016T-MT
Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into
SUPERSERVER 6016T-MT User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the 6016T-MT i
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X8DTL-i serverboard
5-2SUPERSERVER 6016T-MT User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge. When unpa
Chapter 5: Advanced Serverboard Setup5-35-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar
5-4SUPERSERVER 6016T-MT User's Manual5-4 Rear I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-
Chapter 5: Advanced Serverboard Setup5-5!Press the socket clip to release 1. the load plate, which covers the CPU socket, from its locked posi-tion.Ge
SUPERSERVER 6016T-MT User's ManualivChapter 4: System SafetyYou should thoroughly familiarize yourself with this chapter for a general overview
5-6SUPERSERVER 6016T-MT User's ManualAfter removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the north and sout
Chapter 5: Advanced Serverboard Setup5-7Installing a Passive CPU HeatsinkScrew#1Screw#1Screw#2Screw#2Install Screw#1Notes: The serverboard comes with
5-8SUPERSERVER 6016T-MT User's ManualRemoving the HeatsinkWarning: We do not recommend that the CPU or the heatsink be re-moved. However, if you
Chapter 5: Advanced Serverboard Setup5-95-6 Installing Memory ModulesNote: Check the Supermicro web site for recommended memory modules.CAUTIONExerci
5-10SUPERSERVER 6016T-MT User's ManualPopulating DIMMs for Optimal PerformanceFor One CPU (CPU1) Installed (Populate the CPU1 DIMM slots)Branch 0
Chapter 5: Advanced Serverboard Setup5-115-7 Adding PCI CardsThe 6016T-MT includes a CSE-RR1U-E16 riser card. This riser fi ts into a PCI slot to supp
5-12SUPERSERVER 6016T-MT User's ManualFigure 5-4. X8DTL-i LayoutJumpers not indicated are for test purposes only. A square contact pad indicates
Chapter 5: Advanced Serverboard Setup5-13X8DTL-i Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear Open (Normal)JI2C1/JI2C2 SMB to PCI/
5-14SUPERSERVER 6016T-MT User's ManualReset ConnectorThe reset connector is located on pins 3 and 4 of JF1 and attaches to the reset switch on th
Chapter 5: Advanced Serverboard Setup5-15Overheat LED (OH)Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad-vanced warning of c
vPrefaceNotes
5-16SUPERSERVER 6016T-MT User's ManualChassis IntrusionThe Chassis Intrusion header is des-ignated JL1. See the board layout for the location of
Chapter 5: Advanced Serverboard Setup5-17Wake-On-LANThe Wake-On-LAN header is des-ignated JWOL on the serverboard. See the table on the right for pin
5-18SUPERSERVER 6016T-MT User's ManualSGPIO HeadersTwo SGPIO (Serial General Purpose Input/Output) headers are included on the serverboard. These
Chapter 5: Advanced Serverboard Setup5-19LAN1/2 (Ethernet Ports)Two gigabit Ethernet ports (desig-nated LAN1 and LAN2) are located beside the VGA port
5-20SUPERSERVER 6016T-MT User's Manual5-10 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used t
Chapter 5: Advanced Serverboard Setup5-21Watch DogJWD enables the Watch Dog function, a system monitor that takes action when a software application f
5-22SUPERSERVER 6016T-MT User's Manual5-11 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On eac
Chapter 5: Advanced Serverboard Setup5-235-12 SATA PortsSATA PortsThere are no jumpers to en-able the SATA ports, which are designated I-SATA0 ~ I-SAT
5-24SUPERSERVER 6016T-MT User's Manual5-13 Installing SoftwareAfter the hardware has been installed, you should fi rst install the operating syste
Chapter 5: Advanced Serverboard Setup5-25Supero Doctor IIIThe Supero Doctor III program is a Web-based management tool that supports remote management
viSUPERSERVER 6016T-MT User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...
5-26SUPERSERVER 6016T-MT User's ManualNote: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.com/utility
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na
6-2SUPERSERVER 6016T-MT User's ManualFigure 6-2. Chassis Rear View6-2 Control PanelThe control panel (located on the front of the chassis) must
Chapter 6: Advanced Chassis Setup6-36-3 System FansFour 4-cm high-performance fans provide the cooling for the SuperServer 6016T-MT. The chassis inclu
6-4SUPERSERVER 6016T-MT User's ManualFigure 6-4. Mounting a Drive in a CarrierAccessing the Drive BaysSATA Drives: Because of their hotswap capab
Chapter 6: Advanced Chassis Setup6-5Use caution when working around the SATA backplane. Do not touch the backplane with any metal objects and make sur
6-6SUPERSERVER 6016T-MT User's ManualDVD-ROM Drive InstallationThe top cover of the chassis must be opened to gain full access to the DVD-ROM dri
Chapter 6: Advanced Chassis Setup6-76-5 Power SupplyThe SuperServer 6016T-MT has a single 520 watt power supply. This power supply has the capability
6-8SUPERSERVER 6016T-MT User's ManualNotes
Chapter 7: BIOS7-1Chapter 7 BIOS7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTL-i. The AMI ROM BIOS is stored in a Fla
viiTable of Contents2-6 Checking the Drive Bay Setup ... 2-9Chapter 3 System Int
7-2SUPERSERVER 6016T-MT User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory test.
Chapter 7: BIOS7-3Build Date• : This item displays the date when this BIOS was completed.ProcessorThe AMI BIOS will automatically display the status
7-4SUPERSERVER 6016T-MT User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter> to access th
Chapter 7: BIOS7-5Wait For 'F1' If ErrorThis forces the system to wait until the 'F1' key is pressed if an error occurs. The optio
7-6SUPERSERVER 6016T-MT User's ManualXProcessor and Clock OptionsThis submenu allows the user to confi gure the Processor and Clock settings.CPU R
Chapter 7: BIOS7-7Simultaneous Multi-Threading (Available when supported by the CPU)Set to Enabled to use the Simultaneous Multi-Threading Technology,
7-8SUPERSERVER 6016T-MT User's ManualDCA TechnologyThis feature accelerates the performance of TOE devices. Note: A TOE device is a specialized,
Chapter 7: BIOS7-9Channel Mirror - The motherboard maintains two identical copies of all data in memory for redundancy.Lockstep - The motherboard uses
7-10SUPERSERVER 6016T-MT User's ManualAir FlowThis is the air fl ow speed to the DIMM modules. Each step is one mm/sec. The default is [1500]. Pre
Chapter 7: BIOS7-11Active State Power ManagementSelect Enabled to start Active-State Power Management for signal transactions between L0 and L1 Links
viiiSUPERSERVER 6016T-MT User's ManualServerboard Layout ...
7-12SUPERSERVER 6016T-MT User's ManualConfi gure SATA#1 asThis feature allows the user to select the drive type for SATA#1. The options are IDE, R
Chapter 7: BIOS7-13If not, contact your manufacturer or install an ATA/133 IDE controller card that supports 48-bit LBA mode. The options are Disabled
7-14SUPERSERVER 6016T-MT User's ManualSelect MWDMA0 to allow the BIOS to use Multi Word DMA mode 0. It has a data transfer rate of 4.2 MBs. Selec
Chapter 7: BIOS7-15Plug & Play OSSelecting Yes allows the OS to confi gure Plug & Play devices. (This is not required for system boot if your s
7-16SUPERSERVER 6016T-MT User's ManualXRemote Access Confi guration Remote Access This allows the user to enable the Remote Access feature. The op
Chapter 7: BIOS7-17XHardware Health MonitorThis feature allows the user to monitor system health and review the status of each item as displayed.CPU O
7-18SUPERSERVER 6016T-MT User's ManualThe motherboard fans and CPU will run normally as confi gured in the BIOS. The fans may adjust to a faster s
Chapter 7: BIOS7-19tion and allow the onboard fans to constantly run at full speed. The Options are: Disabled, 4-pin (Server), 4-pin (Workstation), 4-
7-20SUPERSERVER 6016T-MT User's ManualHeadless ModeThis feature is used to enable system to function without a keyboard, monitor and/or mouse att
Chapter 7: BIOS7-21Event Dir Type• Event Data.• Clear BMC System Event LogSelect OK and press the <Enter> key to clear the BMC system log. Sele
Table of ContentsixRear UID LED ... 5-225-12 SATA Ports ...
7-22SUPERSERVER 6016T-MT User's ManualGateway AddressThis is the IP address of the gateway in the network. This is usually a router.Mac Address T
Chapter 7: BIOS7-23BMC Watch Dog TimeOut [Min:Sec]This option appears if BMC Watch Dog Timer Action (above) is enabled. This is a timed delay in minut
7-24SUPERSERVER 6016T-MT User's ManualSupervisor Password This item indicates if a Supervisor password has been entered for the system. "Not
Chapter 7: BIOS7-25XBoot Device PriorityThis feature allows the user to specify the sequence of priority for the Boot Device. The settings are 1st boo
7-26SUPERSERVER 6016T-MT User's ManualSave Changes and ExitWhen you have completed the system confi guration changes, select this option to leave
A-1Appendix A: BIOS POST Error CodesAppendix A BIOS Post Error Codes During the POST (Power-On Self-Test) routines, which are performed each time the
A-2SUPERSERVER 6016T-MT User's ManualNotes
Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure Intel South
B-2SUPERSERVER 6016T-MT User's ManualB-2 Installing the Windows OS to a Non-RAID SystemInsert Microsoft's Windows setup CD in the CD Driver
C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessors Two Intel® 5500 Series processors in LGA1366 sockets Note: p
Comentarios a estos manuales