SUPERSERVER 6016T-6RFT+SUPERSERVER 6016T-6RF+ SUPER®USER’S MANUAL1.0
1-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6016T-6RFT+/6016T-6RF+ lies the X8DTU-
7-28SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual7-6 Exit OptionsSelect the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit
Chapter 7: BIOS7-29Load Fail-Safe DefaultsTo set this feature, select Load Fail-Safe Defaults from the Exit menu and press <Enter>. The Fail-Saf
7-30SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNotes
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the
A-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNotes
B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessors Single or dual Intel® 5500/5600 Series processors in LGA1366 soc
B-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualServerboard 6016T-6RFT+: X8DTU-6TF+ (Proprietary form factor) 6016T-6RF+: X8DTU-6F
B-3Appendix B: System Specifi cationsRegulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 C
B-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNotes(continued from front)The products sold by Supermicro are not intended for and will not b
1-3Chapter 1: Introduction10 supported (RAID 5 is supported with Windows OS only). The SATA drives are hot-swappable units. Note: You must have RAID s
1-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualPCI Expansion SlotsTwo riser cards are included. The RSC-R1UU-E8R+ is located on the right sid
1-5Chapter 1: IntroductionFigure 1-1. Intel 5520 + IOH-36D/ICH10R Chipset: System Block DiagramNote: This is a general block diagram. Please see Chap
1-6SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your 6016T-6RFT+/6016T-
2-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual!!Warnings and Precautions!installation only in a Restricted Access Location (dedicated equipm
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
2-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual2-4 Installing the System into a RackThis section provides information on installing the 6016
Chapter 2: Server Installation2-5Installing the Outer RailsInstalling the Outer Rails to the RackMeasure the distance from the front rail to the rear
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur
2-6SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualInstalling the Server into the RackInstalling the Chassis into a Rack (Figure 2-3)Confi rm that
Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a Rack
2-8SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual2-5 Checking the Serverboard SetupAfter you install the system in the rack, you will need to
Chapter 2: Server Installation2-9Figure 2-4. Accessing the Inside of the System
2-10SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual2-6 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives an
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the hard drive ca
3-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualHDDIndicates IDE channel activity. On the 6016T-6RFT+/6016T-6RF+ this light indicates HDD and/
Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated
3-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNotes
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta
4-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual4-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area aroun
Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into
4-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual4-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install processors and heatsinks
5-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual5-2 Processor and Heatsink InstallationIMPORTANT! Always connect the power cord last and remo
Chapter 5: Advanced Serverboard Setup5-3After removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the north and south
5-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualThermal GreaseCPUPlace the heatsink on top of the 1. CPU so that the four mounting holes are a
Chapter 5: Advanced Serverboard Setup5-5Unplug the power cord from the power supply.1. Unscrew and remove the heatsink screws in the 1. sequence shown
5-6SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual5-3 Connecting CablesNow that the processors are installed, the next step is to connect the ca
Chapter 5: Advanced Serverboard Setup5-7Figure 5-1. Front Control Panel Header Pins (JF1)NMIx (key)3.3VUID Switch/VccNIC1 Active LEDNIC2 Active LEDRed
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X8DTU-6TF+
5-8SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual5-5 Installing MemoryNote: Check the Supermicro web site for recommended memory modules.CAUTIO
Chapter 5: Advanced Serverboard Setup5-9Memory Support for 5500 Processor(s)RDIMM Population w/5500 Processors InstalledDIMM Slots per ChannelDIMMs Po
5-10SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNotes: Due to OS limitations, some operating systems may not show more than 4 GB of memory. D
Chapter 5: Advanced Serverboard Setup5-11Possible System Memory Allocation & AvailabilitySystem Device Size Physical Memory Remaining (4 GB Total
5-12SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualPCI Slot/Card Confi gurationsRiser Card Expansion Card SupportedRSC-R1UU-2E8 (left side) 1x UI
Chapter 5: Advanced Serverboard Setup5-13Figure 5-4. SUPER X8DTU-6TF+/ Layout5-7 Serverboard DetailsNotes:TLAN1 and TLAN 2 are included on the X8DTU-
5-14SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualX8DTU-6TF+/X8DTU-6F+ Quick ReferenceJumper Description Default SettingJBT1Clear CMOS See Sect
Chapter 5: Advanced Serverboard Setup5-155-8 Connector Defi nitionsATX Power Connector The primary ATX power supply con-nector meets the SSI EPS 12V sp
5-16SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNIC1 LEDThe NIC1 (Network Interface Control-ler) LED connection is located on pins 11 and 12
Chapter 5: Advanced Serverboard Setup5-17Overheat (OH)/Fan Fail/PWR Fail/UID LEDConnect an LED to pins 7 and 8 of JF1 to provide advanced warning of c
vPrefaceNotes
5-18SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualFan HeadersThe board has eight fan headers designated Fan1 through Fan8. FAN1 through FAN6 ar
Chapter 5: Advanced Serverboard Setup5-19Chassis Intrusion A Chassis Intrusion header is located at JL1. Attach the appropriate cable to inform you of
5-20SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualLAN (Ethernet) PortsTwo Ethernet ports (designated LAN1 and LAN2) are located beside the VGA
Chapter 5: Advanced Serverboard Setup5-21Universal I/O Power ConnectorPin Defi nitions Pin# Defi nition Pin # Defi nitionB1 P5V A1 P3V3B2 P5
5-22SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualTrusted Platform Module HeaderA Trusted Platform Module header (JTPM) is located next to the
Chapter 5: Advanced Serverboard Setup5-235-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to c
5-24SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualLAN/TLAN Enable/Disable Change the setting of jumper JPL1 to enable or disable the LAN1 and L
Chapter 5: Advanced Serverboard Setup5-255-10 Onboard IndicatorsLAN LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each Gigabi
5-26SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualBMC Heartbeat LEDState Defi nition Blinking BMC: NormalSAS Activity & SAS Heart
Chapter 5: Advanced Serverboard Setup5-275-11 SATA Port ConnectionsSATA PortsThere are six Serial ATA Ports (I-SATA0~I-SATA 5) on the serverboard, wh
viSUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...
5-28SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual5-12 Installing SoftwareAfter the hardware has been installed, you should fi rst install the o
Chapter 5: Advanced Serverboard Setup5-29Supero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote management
5-30SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNote: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermic
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na
6-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualFigure 6-1. Chassis: Front and Rear Views6-2 Control PanelThe control panel (located on the f
Chapter 6: Advanced Chassis Setup6-36-3 System FansFive 4-cm heavy duty counter-rotating fans provide the cooling for the 6016T-6RFT+/6016T-6RF+. Each
6-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualFigure 6-2. System Cooling FansAccessing the Drive BaysHard Drives: Because of their hotswap
Chapter 6: Advanced Chassis Setup6-5Hard Drive InstallationThe hard drives are mounted in drive carriers to simplify their installation and removal fr
6-6SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualInstalling/Removing a Hard DriveTo remove a carrier, push the release button located beside th
Chapter 6: Advanced Chassis Setup6-7DVD-ROM Drive InstallationThe top cover of the chassis must be opened to gain full access to the DVD-ROM drive bay
viiTable of Contents2-5 Checking the Serverboard Setup ... 2-8Chapter 3 System Inter
6-8SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual6-4 Power SupplyThe SuperServer 6016T-6RFT+/6016T-6RF+ has a 700 watt redundant power supply c
Chapter 6: Advanced Chassis Setup6-9Figure 6-5. Removing/Replacing the Power Supply12
6-10SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNotes
Chapter 7: BIOS7-1Chapter 7 BIOS7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTU-6F+/X8DTU-6TF+. The AMI ROM BIOS is st
7-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNote: For AMI BIOS Recovery, please refer to the AMI BIOS Recovery Instructions posted on our
Chapter 7: BIOS7-3System Overview: The following BIOS information will display.System Time/System Date Use this option to change the system time and d
7-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Advanced and press <Enter>
Chapter 7: BIOS7-5Hit 'Del' Message DisplaySelect Enabled to display "Press DEL to run Setup" during POST. The options are Enabled
7-6SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualCache L2• : This item displays the size of Cache L2 of the CPU for the moth-erboard.Cache L3•
Chapter 7: BIOS7-7Intel® Virtualization Technology (Available when supported by the CPU)Select Enabled to use the feature of Virtualization Technology
viiiSUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual5-10 Onboard Indicators ...
7-8SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualC1E SupportSelect Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces
Chapter 7: BIOS7-9Memory Reference Code:• This item displays the memory reference code for the motherboard.QPI Reference Code:• This item displays
7-10SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualChannel InterleaveThis feature allows the user to confi gure the Memory Interleave settings fo
Chapter 7: BIOS7-11IOH PCI-E Max Payload SizeSome add-on cards perform faster with the coalesce feature, which limits the payload size to 128B; while
7-12SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualSATA#1 Confi gurationIf Compatible is selected, it sets SATA#1 to legacy compatibility mode, w
Chapter 7: BIOS7-13LBA/Large ModeLBA (Logical Block Addressing) is a method of addressing data on a disk drive. In the LBA mode, the maximum drive cap
7-14SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualSelect SWDMA2 to allow the BIOS to use Single Word DMA mode 2. It has a data transfer rate of
Chapter 7: BIOS7-15Plug & Play OSSelecting Yes allows the OS to confi gure Plug & Play devices. (This is not required for system boot if Plug &
7-16SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualXSuper IO Device Confi guration Serial Port1 Address/ Serial Port2 AddressThis option specifi e
Chapter 7: BIOS7-17to keep Console Redirection active during POST and Boot Loader. The options are Disabled, Boot Loader, and Always.Terminal TypeThis
Chapter 1 Introduction1-1 OverviewThe SuperServer 6016T-6RFT+/6016T-6RF+ is a high-end server comprised of two main subsystems: the SC819TQ-R700U 1U s
7-18SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualCPU 1 Temperature/CPU 2 Temperature/System TemperatureThis feature displays current temperatu
Chapter 7: BIOS7-192. The information provided above is for your reference only. For more information on thermal management, please refer to Intel’s W
7-20SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualACPI APIC Support (Available ACPI Aware O/S='Yes')Select Enabled to include the ACP
Chapter 7: BIOS7-21BIOS AC[SCLEAN] (Available when Intel TXT(LT) Initialization is enabled)Select Enabled to allow the processor to load an authentica
7-22SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualExecute TPM Command (Available when TCG/TPM Support = 'Yes')Select Enabled to execu
Chapter 7: BIOS7-23SEL Record Type• Event Timestamp• Generator ID• Event Message Format Ver.• Event Sensor Type• Event Sensor Number,• Event Dir Type•
7-24SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manualassigned to the client can be reassigned to a new client. Select Static (Static Allocation) t
Chapter 7: BIOS7-25after an operating system failure is detected. The options are [5 Min], [1 Min], [30 Sec], and [10 Sec].XDMI Event Log Confi guratio
7-26SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualSupervisor Password This item indicates if a Supervisor password has been entered for the sys
Chapter 7: BIOS7-277-5 Boot Confi gurationUse this feature to confi gure boot settings. XBoot Device PriorityThis feature allows the user to specify the