®SUPER STORAGE SYSTEM2027R-E1R24L SUPERUSER’S MANUAL1.0
Chapter 1 Introduction1-1 OverviewThe 2027R-E1R24L is a high-end storage system comprised of two main subsys-tems: the SC216E16-R920LPB 2U/rack mount
Chapter 7: BIOS7-7Execute-Disable Bit (Available if supported by the OS & the CPU)Select Enabled to enable the Execute Disable Bit which will allo
7-8SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualX CPU Power Management Confi gurationThis submenu allows the user to confi gure the following CPU P
Chapter 7: BIOS7-9Package C-State limit (Available when Power Technology is set to Custom)This feature allows the user to set the limit on the C-State
7-10SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualXChipset Confi gurationXNorth BridgeThis feature allows the user to confi gure the settings for th
Chapter 7: BIOS7-11IIO 2 PCIe Port Bifurcation ControlThis submenu confi gures the following IO PCIe Port Bifurcation Control settings for IIO 2 PCIe p
7-12SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualXDIMM InformationCPU Socket 1 DIMM Information, CPU Socket 2 DIMM InformationThe status of the m
Chapter 7: BIOS7-13correctable error, the error is corrected and sent to the requestor (the original source). Memory is updated as well. Select Enable
7-14SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualPort 60/64 EmulationSelect Enabled to enable I/O port 60h/64h emulation support for the legacy U
Chapter 7: BIOS7-15Port 0~5 Hot PlugSelect Enabled to enable hot-plug support for a particular port, which will allow the user to change a hardware co
7-16SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualSERR# GenerationSelect Enabled to allow a PCI device to generate an SERR number for a PCI Bus Si
1-2SUPERSTORAGESYSTEM 2027R-E1R24L User's Manual1-2 Serverboard FeaturesThe 2027R-E1R24L is built around the X9DRD-7LN4F-JBOD, a dual processor s
Chapter 7: BIOS7-17VGA PriorityThis feature allows the user to select the graphics adapter to be used as the primary boot device. The options are Onbo
7-18SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualChange SettingsThis option specifi es the base I/O port address and the Interrupt Request address
Chapter 7: BIOS7-19client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 38400, 57600 and
7-20SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualPutty KeyPadThis feature selects Function Keys and KeyPad settings for Putty, which is a termina
Chapter 7: BIOS7-21Data Bits, Parity, Stop BitsThe status of these features is displayed.XACPI SettingsUse this feature to confi gure Advanced Confi gur
7-22SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualPending OperationUse this item to schedule an operation for the security device. The options are
Chapter 7: BIOS7-23TPM Support: Trusted Platform supportTPM State: Trusted Platform stateXME SubsystemThis feature displays the following ME Subsystem
7-24SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualBlink LEDs This feature allows the user to specify the duration for LEDs to blink. The range is
Chapter 7: BIOS7-257-4 Event LogsSelect the Event Logs tab to access the following submenu items.XChange SMBIOS Event Log SettingsThis feature allow
7-26SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualErasing SettingsErase Event LogSelect Enabled to erase the SMBIOS (System Management BIOS) Event
1-3Chapter 1: Introduction1-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC216E16-R920LPB server chassis.S
Chapter 7: BIOS7-277-5 IPMISelect the IPMI (Intelligent Platform Management Interface) tab to access the fol-lowing submenu items.IPMI Firmware Revi
7-28SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualWhen SEL is FullThis feature allows the user to decide what the BIOS should do when the system e
Chapter 7: BIOS7-29Gateway IP AddressThis item displays the Gateway IP address for this computer. This should be in decimal and in dotted quad form (i
7-30SUPERSTORAGESYSTEM 2027R-E1R24L User's Manual7-7 SecurityThis menu allows the user to confi gure the following security settings for the sys
Chapter 7: BIOS7-317-8 Save & ExitThis submenu allows the user to confi gure the Save and Exit settings for the system.Discard Changes and Exit S
7-32SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualDiscard ChangesSelect this feature and press <Enter> to discard all the changes and return
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed at each system
A-2SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualNotes
B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessorsSingle or dual Intel® Xeon E5-2600 Series processorsNote: Please refer t
B-2SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualChassisSC216E16-R920LPB, 2U rackmountDimensions: (WxHxD) 17.2 x 3.5 x 24.8 in. (437 x 89 x 630 mm
1-4SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualFigure 1-1. Intel C602J Chipset: System Block DiagramNote: This is a general block diagram. Plea
B-3Appendix B: System Specifi cationsRegulatory ComplianceElectromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A
B-4SUPERSTORAGESYSTEM 2027R-E1R24L User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used i
1-5Chapter 1: IntroductionFigure 1-2. X9DRD-7LN4F-JBOD ServerboardNote: The SSG-2027R-E1R24L comes pre-installed with a JBOD expansion port installed
1-6SUPERSTORAGESYSTEM 2027R-E1R24L User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, C
Chapter 2: Server Installation2-1Chapter 2Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 2027R-E
2-2SUPERSTORAGESYSTEM 2027R-E1R24L User's Manual• This product is not suitable for use with visual display work place devices acccording to §2 of
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
2-4SUPERSTORAGESYSTEM 2027R-E1R24L User's Manual2-4 Rack Mounting InstructionsThis section provides information on installing the chassis into a
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur
Chapter 2: Server Installation2-5Figure 2-2. Extending and Releasing the Inner Rail12111314Locking TabsEach inner rail has a locking tab. This tab lo
2-6SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualFigure 2-4. Inner Rails Installed on the Chassis(The chassis above are an example only. Actual c
Chapter 2: Server Installation2-7Installing the Outer Rails on the RackInstalling the Outer Rails1. Press upward on the locking tab at the rear end o
2-8SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualFigure 2-6. Installing into a RackStandard Chassis InstallationInstalling the Chassis into a Rack
Chapter 2: Server Installation2-9Optional Quick Installation MethodThe following quick installation method may be used to install the chassis onto a r
2-10SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualNotes
Chapter 3: System Interface3-1Chapter 3System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the Hard drive car
3-2SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualPower FailIndicates a power supply module has failed. The second power supply module will take th
Chapter 3: System Interface3-3HDDIndicates IDE channel activity. On the SuperServer 2027R-E1R24L, this LED indi-cates hard and/or DVD-ROM drive activi
3-4SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualNotes
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta
4-1Chapter 4: Warning Statements for AC SystemsChapter 4Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe fo
4-2SUPERSERVER 2027R-E1R24L User's ManualWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situat
4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확
4-4SUPERSERVER 2027R-E1R24L User's ManualInstallation Instructions Warning! Read the installation instructions before connecting the system to th
4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning! This product relies on the building's installation for short-circuit (ove
4-6SUPERSERVER 2027R-E1R24L User's ManualPower Disconnection Warning Warning!The system must be disconnected from all sources of power and the po
4-7Chapter 4: Warning Statements for AC SystemsLe système doit être débranché de toutes les sources de puissance ainsi que de son cordon d'alimen
4-8SUPERSERVER 2027R-E1R24L User's ManualEquipment Installation Warning! Only trained and qualifi ed personnel should be allowed to install, repla
4-9Chapter 4: Warning Statements for AC Systems Warning! This unit is intended for installation in restricted access areas. A restricted access area c
4-10SUPERSERVER 2027R-E1R24L User's ManualBattery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Repl
SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X9DRD-7LN4F-J
4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur
4-12SUPERSERVER 2027R-E1R24L User's ManualWarnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein tr
4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is
4-14SUPERSERVER 2027R-E1R24L User's ManualComply with Local and National Electrical Codes Warning! Installation of the equipment must comply with
4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning! Ultimate disposal of this product should be handled according to all nationa
4-16SUPERSERVER 2027R-E1R24L User's ManualWaarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met a
4-17Chapter 4: Warning Statements for AC SystemsWarnungDie Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halt
4-18SUPERSERVER 2027R-E1R24L User's Manual Warning!When installing the product, use the provided or designated connection cables, power cables an
4-19Chapter 4: Warning Statements for AC SystemsAttention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné
4-20SUPERSERVER 2027R-E1R24L User's ManualNotes
NotesPrefacev
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to connect the data and power cable
5-2SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge
Chapter 5: Advanced Serverboard Setup5-35-3 Rear I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2
5-4SUPERSTORAGESYSTEM 2027R-E1R24L User's Manual5-4 Installing the Processor and HeatsinkWhen handling the processor package, avoid placing dire
Chapter 5: Advanced Serverboard Setup5-5Gently push down to pop the load plate open.3. With the lever labeled 'Close 1st' fully retracted,
5-6SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualWarning: You can only install the CPU to the socket in one direction. Make sure that the CPU is
Chapter 5: Advanced Serverboard Setup5-7Installing a Passive CPU Heatsink1. Do not apply any thermal grease to the heatsink or the CPU die -- the re-
5-8SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualRemoving the HeatsinkWarning: We do not recommend that the CPU or the heatsink be removed. How-ev
Chapter 5: Advanced Serverboard Setup5-9Memory SupportThe X9DRD-7LN4F-JBOD has 16 DIMM slots that can support 512 GB of ECC DDR3 Registered memory (RD
5-10SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualDIMM Module Population TablesProcessors and their Corresponding Memory ModulesCPU# Corresponding
viTable of ContentsChapter 1 Introduction1-1 Overview ...
Chapter 5: Advanced Serverboard Setup5-11Intel E5-2600 Series Processor RDIMM Memory SupportRanks Per DIMM & Data WidthMemory Capacity Per DIMM(Se
5-12SUPERSTORAGESYSTEM 2027R-E1R24L User's Manual1 CPU, 2 DIMMs1 CPU, 5-8 DIMMs1 CPU, 4 DIMMsJPME1JI2C1VGA1I-SATA1I-SATA0I-SATA5I-SATA4I-SATA3I-S
Chapter 5: Advanced Serverboard Setup5-132 CPU, 6 DIMMs2 CPU, 8 DIMMs 2 CPU, 10-16 DIMMsFor two CPUs and 16 DIMMs, populate all DIMM slots.Populate bl
5-14SUPERSTORAGESYSTEM 2027R-E1R24L User's Manual5-6 Adding PCI Add-On CardsThe 2027R-E1R24L can accommodate up to fi ve low-profi le PCI-E 3.0 x8
Chapter 5: Advanced Serverboard Setup5-15Figure 5-4. X9DRD-7LN4F-JBOD Layout5-7 Serverboard DetailsNotesJumpers not indicated are for test purposes on
5-16SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualX9DRD-7LN4F-JBOD Quick Reference Jumper Description Default SettingJBT1 Clear CMOS See Section 5
Chapter 5: Advanced Serverboard Setup5-17LED Description StateLED2 Standby PWR LED Solid Green (Standby Power On)LED3 UID LED Blue: On (Unit Identifi e
5-18SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualReset ButtonThe Reset Button connection is located on pins 3 and 4 of JF1 and attaches to the re
Chapter 5: Advanced Serverboard Setup5-19Overheat/Fan Fail/PWR Fail LEDConnect an LED to the OH connection on pins 7 and 8 of JF1 for the Over-heat/Fa
5-20SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualFan HeadersThere are eight fan headers on the serverboard, all of which are 4-pin fans. Pins 1-3
viiChapter 3 System Interface3-1 Overview ... 3-
Chapter 5: Advanced Serverboard Setup5-21Ethernet PortsFour Ethernet ports are located on the I/O backplane. A dedicated IPMI LAN port is also include
5-22SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualUniversal Serial Bus (USB)There are four Universal Serial Bus ports (USB0/1/2/3) located on the
Chapter 5: Advanced Serverboard Setup5-23IPMBA System Management Bus header for IPMI 2.0 is located at IPMB. Con-nect the appropriate cable here to us
5-24SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualTPM Header/Port 80A Trusted Platform Module/Port 80 header is located at JTPM1 to provide TPM su
Chapter 5: Advanced Serverboard Setup5-255-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to c
5-26SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualVGA Enable/DisableJPG1 allows you to enable or disable the VGA port. The default position is on
Chapter 5: Advanced Serverboard Setup5-275-10 Onboard IndicatorsLAN LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each port,
5-28SUPERSTORAGESYSTEM 2027R-E1R24L User's Manual5-11 SATA PortsSATA PortPin Defi nitionsPin# Defi nition Pin Defi nition1 Ground 2
Chapter 5: Advanced Serverboard Setup5-295-12 Installing SoftwareAfter the hardware has been installed, you should fi rst install the operating system
5-30SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualSupero Doctor III Interface Display Screen (Health Information)SuperDoctor IIIThe SuperDoctor®
viiiInstalling a Passive CPU Heatsink ... 5-7Removing the Heatsink ...
Chapter 5: Advanced Serverboard Setup5-31Supero Doctor III Interface Display Screen (Remote Control)Note: The SuperDoctor III program and User's
5-32SUPERSTORAGESYSTEM 2027R-E1R24L User's Manual5-13 Onboard BatteryCare must be taken to assure that the chassis cover is in place when the 202
Chapter 6: Advanced Chassis Setup6-1Chapter 6Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-nan
6-2SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualFigure 6-1. Front and Rear Chassis Views6-2 Control PanelThe control panel (located on the front
Chapter 6: Advanced Chassis Setup6-36-3 Removing the Chassis CoverFigure 6-2. Removing the Chassis CoverRemoving the Chassis CoverYou may need to ga
6-4SUPERSTORAGESYSTEM 2027R-E1R24L User's Manual6-4 System CoolingSystem FansThree 8-cm hot-swap chassis fans provide the cooling for the SuperSe
Chapter 6: Advanced Chassis Setup6-5Air ShroudsAir shrouds concentrate airfl ow to maximize fan effi ciency. The SC216 chassis air shrouds do not requir
6-6SUPERSTORAGESYSTEM 2027R-E1R24L User's Manualbreak-away pieces that may be removed to accomodate differing styles of motherboards. An addition
Chapter 6: Advanced Chassis Setup6-76-5 Drive Bay Installation/RemovalAccessing the Drive BaysSAS/SATA Drives: You do not need to access the inside o
6-8SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualWarning! Enterprise level hard disk drives are recommended for use in Supermicro chassis and serv
7-4 Event Logs ... 7-257-5 IPMI ...
Chapter 6: Advanced Chassis Setup6-9Figure 6-6. Mounting a SATA Drive in a CarrierFigure 6-7. Proper Installation of the Carrier into Hard Drive BayIn
6-10SUPERSTORAGESYSTEM 2027R-E1R24L User's Manual6-5 Power Supply The 2027R-E1R24L chassis has two redundant 920 Watt power supplies. The power m
Chapter 6: Advanced Chassis Setup6-11Changing the Power Supply 1. Determine which power supply needs to be replaced and unplug the power cord to that
6-12SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualFigure 6-9. JBOD Expansion PortJBOD OUT (downstream port)6-6 Attaching a JBOD Expansion
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup utility for the X9DRD-7LN4F-JBOD It also provides the ins
7-2SUPERSTORAGESYSTEM 2027R-E1R24L User's ManualHow To Change the Confi guration DataThe confi guration data that determines the system parameters
Chapter 7: BIOS7-3The AMI BIOS Main menu displays the following information:System Date/System TimeUse this option to change the system time and date.
7-4SUPERSTORAGESYSTEM 2027R-E1R24L User's Manual7-3 Advanced Setup Confi gurationsSelect the Advanced tab to access the following submenu items.
Chapter 7: BIOS7-5at bootup and allow the drives that are attached to these host adaptors to function as bootable disks. If this item is set to Disabl
7-6SUPERSTORAGESYSTEM 2027R-E1R24L User's Manual• Processor Cores• Intel HT (Hyper-Threading) Technology• Intel VT-x Technology• Intel SMX Techno
Comentarios a estos manuales