SUPERSUPERSERVER 8015C-T®USER’S MANUALRevision 1.0

Pagina 2 - Manual Revision 1.0

1-2SUPERSERVER 8015C-T User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 8015C-T lies the X7QCE, a quad processor serverboard

Pagina 3 - Manual Organization

B-2SUPERSERVER 8015C-T User's ManualPOST Code Description14h Initialize keyboard controller16h 1-2-2-3 BIOS ROM checksum17h Initial

Pagina 4

Appendix B: BIOS POST CodesB-3POST Code Description5Bh Disable CPU cache5Ch Test RAM between 512 and 640 kB60h Test extended memory62h

Pagina 5

B-4SUPERSERVER 8015C-T User's ManualPOST Code Description99h Check for SMART Drive (optional)9Ch Set up Power Management9Dh Initial

Pagina 6 - Table of Contents

Appendix B: BIOS POST CodesB-5The following are for the boot block in Flash ROMPOST Code DescriptionE0h Initialize the chipsetE1h Initialize

Pagina 7 - Chapter 4 System Safety

B-6SUPERSERVER 8015C-T User's ManualNotes

Pagina 8

Appendix C: Intel HostRAID Setup GuidelinesC-1Appendix C HostRAID Setup GuidelinesAfter all the hardware has been installed, you must fi rst confi gure

Pagina 9 - Introduction

C-2SUPERSERVER 8015C-T User's ManualThe Intel HostRAID Confi gurationsThe following types of Intel's HostRAID confi gurations are supported:RA

Pagina 10 - 1-2 Serverboard Features

Appendix C: Intel HostRAID Setup GuidelinesC-3Using the Intel ESB2 SATA RAID Utility ProgramCreating, Deleting and Resetting RAID Volumes:After the sy

Pagina 11 - Other Features

C-4SUPERSERVER 8015C-T User's ManualCreating a RAID 0 VolumeSelect "Create RAID Volume" from the main menu and press the <Enter>

Pagina 12 - 1-3 Server Chassis Features

Appendix C: Intel HostRAID Setup GuidelinesC-5Creating a RAID 1 Volume:Select "Create RAID Volume" from the main menu and press the <Ente

Pagina 13 - System Block Diagram

1-3Chapter 1: IntroductionThe X7QCE features an integrated ATI video controller based on the ES1000 graph-ics chip. The ES1000 was designed specifi ca

Pagina 14 - 1-4 Contacting Supermicro

C-6SUPERSERVER 8015C-T User's ManualCreating a RAID 10 (RAID 1+ RAID 0)Select "Create RAID Volume" from the main menu and press the <

Pagina 15 - Server Installation

Appendix C: Intel HostRAID Setup GuidelinesC-7Creating a RAID 5 Set (Parity)Select "Create RAID Volume" from the main menu and press the <

Pagina 16 - Warnings and Precautions!

C-8SUPERSERVER 8015C-T User's ManualDeleting a RAID VolumePress Enter when the Create Volume item is highlighted. A warning message displays.When

Pagina 17 - Rack Mounting Considerations

Appendix C: Intel HostRAID Setup GuidelinesC-9From the main menu, select "Reset Disks to Non- RAID" and press <Enter>. The following s

Pagina 18 - Installing the Inner Rails

C-10SUPERSERVER 8015C-T User's ManualC-2 Installing Windows XP/2000/2003 for RAID SystemsInstalling a New Operating SystemInsert the Microsoft t

Pagina 19 - Installing the Outer Rails

D-1Appendix D: System Specifi cationsAppendix D System Specifi cationsProcessors Four Intel Xeon 7300/7200 sequence processors (130W CPUs not supp

Pagina 20

D-2SUPERSERVER 8015C-T User's ManualWeight Gross (Bare Bone): 43 lbs. (19.5 kg.) System Cooling Six (6) paired sets of 4-cm c

Pagina 21

D-3Appendix D: System Specifi cationsCalifornia Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only

Pagina 22

D-4SUPERSERVER 8015C-T User's ManualNotes

Pagina 23 - 2-6 Preparing to Power On

1-4SUPERSERVER 8015C-T User's Manual1-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC818TQ-1000 server

Pagina 24

1-5Chapter 1: IntroductionFigure 1-1. Intel 7300 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details

Pagina 25 - System Interface

1-6SUPERSERVER 8015C-T User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S

Pagina 26 - 3-3 Control Panel LEDs

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your 8015C-T up and ru

Pagina 27 - 3-4 SATA Drive Carrier LEDs

2-2SUPERSERVER 8015C-T User's ManualWarnings and Precautions!Rack PrecautionsEnsure that the leveling jacks on the bottom of the rack are fully e

Pagina 28

Chapter 2: Server Installation2-3Allow the hot plug SATA drives and power supply modules to cool before touch-ing them.Always keep the rack's fro

Pagina 29 - System Safety

2-4SUPERSERVER 8015C-T User's Manual2-4 Installing the System into a RackThis section provides information on installing the 8015C-T into a rack

Pagina 30

Chapter 2: Server Installation2-5Installing the Outer RailsBegin by measuring the distance from the front rail to the rear rail of the rack. Attach a

Pagina 31 - 4-3 ESD Precautions

Manual Revision 1.0Release Date: September 12, 2007The information in this User’s Manual has been carefully reviewed and is believed to be accurate.

Pagina 32 - BATTERY HOLDER BATTERY HOLDER

2-6SUPERSERVER 8015C-T User's ManualFigure 2-3. Installing the Server into a RackInstalling the Server into the RackYou should now have rails att

Pagina 33 - Advanced Serverboard Setup

Chapter 2: Server Installation2-72-5 Checking the Serverboard SetupAfter you install the 8015C-T in the rack, you will need to open the top cover to

Pagina 34 - 5-2 Serverboard Installation

2-8SUPERSERVER 8015C-T User's ManualFigure 2-4. Accessing the Inside of the System

Pagina 35 - 5-3 Connecting Cables

Chapter 2: Server Installation2-92-6 Preparing to Power OnNext, you should check to make sure the peripheral drives and the SATA drives and SATA back

Pagina 36 - 20 19

2-10SUPERSERVER 8015C-T User's ManualNotes

Pagina 37

Chapter 3: System Interface3-1PowerThe main power button is used to apply or remove power from the power supply to the server system. Turning off syst

Pagina 38

3-2SUPERSERVER 8015C-T User's Manual21NIC2Indicates network activity on GLAN2 when fl ashing .3-3 Control Panel LEDsThe control panel located on t

Pagina 39

Chapter 3: System Interface3-33-4 SATA Drive Carrier LEDsGreen: Each Serial ATA drive carrier has a green LED. When illuminated, this green LED (on th

Pagina 40 - 5-6 Installing Memory

3-4SUPERSERVER 8015C-T User's ManualNotes

Pagina 41 - DDR2 FBD DIMM

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Pagina 42 - 5-8 Serverboard Details

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an

Pagina 43 - X7QCE Quick Reference

SUPERSERVER 8015C-T User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area around the SuperServe

Pagina 44 - 5-9 Connector Defi nitions

Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic discharge (ESD) is generated by two objects with different electrical charges coming into

Pagina 45

SUPERSERVER 8015C-T User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the 8015C-T is

Pagina 46

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X7QCE serverboard in

Pagina 47

5-2SUPERSERVER 8015C-T User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge. When unpa

Pagina 48

Chapter 5: Advanced Serverboard Setup5-35-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar

Pagina 49

5-4SUPERSERVER 8015C-T User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 below

Pagina 50 - 5-10 Jumper Settings

Chapter 5: Advanced Serverboard Setup5-55-5 Installing the Processor and Heatsink!Avoid placing direct pressure to the top of the processor package.

Pagina 51

5-6SUPERSERVER 8015C-T User's ManualCPU InstallationLift the lever on the CPU socket completely as shown in the picture on the right; otherwise,

Pagina 52

Chapter 5: Advanced Serverboard Setup5-7CEK Heat Sink InstallationDo not apply any thermal grease to the heat sink or the CPU die; the required amount

Pagina 53

SUPERSERVER 8015C-T User's ManualivChapter 5 provides detailed information on the X7QCE serverboard, including the locations and functions of con

Pagina 54 - 5-11 Onboard Indicators

5-8SUPERSERVER 8015C-T User's ManualMemory SupportThe X7QCE supports up to 192 GB fully buffered (FBD) ECC DDR2 667/533 in 24 DIMM slots (four ch

Pagina 55

Chapter 5: Advanced Serverboard Setup5-9To Install: Insert module vertically and press down until it snaps into place. Pay attention to the bottom no

Pagina 56

5-10SUPERSERVER 8015C-T User's ManualFigure 5-5. X7QCE Layout(not drawn to scale)5-8 Serverboard DetailsPCI Slot4 PCI-X 133MHzJVGA1JCOM1J19J13JCO

Pagina 57 - Advanced Chassis Setup

Chapter 5: Advanced Serverboard Setup5-11X7QCE Quick ReferenceJumper Description Default SettingJ10/J11 SMB to PCI Slots #3/#4/#5/#6 Pins 1/2 (Enabled

Pagina 58 - 6-2 Control Panel

5-12SUPERSERVER 8015C-T User's ManualReset ConnectorThe reset connector is located on pins 3 and 4 of JF1 and attaches to the reset switch on the

Pagina 59 - 6-3 System Fans

Chapter 5: Advanced Serverboard Setup5-13Overheat/Fan Fail LED (OH)Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad-vanced war

Pagina 60 - 6-4 Drive Bay Installation

5-14SUPERSERVER 8015C-T User's ManualFan HeadersThere are nine fan headers on the serverboard, all of which are 4-pin fans. However, pins 1-3 of

Pagina 61 - Accessing the Drive Bays

Chapter 5: Advanced Serverboard Setup5-15Wake-On-LANThe Wake-On-LAN header is des-ignated JWOL1 on the serverboard. See the table on the right for pi

Pagina 62 - SATA Drive Installation

5-16SUPERSERVER 8015C-T User's ManualSerial PortsTwo serial ports are included on the serverboard. COM1 is a backpanel port and COM2 is a header

Pagina 63 - SATA Backplane

Chapter 5: Advanced Serverboard Setup5-17Power SMB (I2C) ConnectorPower SMB (I2 C) connector, located at J13, monitors the status of the power supply,

Pagina 64

vPrefaceNotes

Pagina 65 - 6-5 Power Supply

5-18SUPERSERVER 8015C-T User's Manual5-10 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to

Pagina 66

Chapter 5: Advanced Serverboard Setup5-19CMOS ClearJBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper con

Pagina 67 - Chapter 7

5-20SUPERSERVER 8015C-T User's ManualCompact Flash Master/Slave SelectA Compact Flash Master (Primary)/Slave (Secondary) Select Jumper is located

Pagina 68 - 7-2 Main Setup

Chapter 5: Advanced Serverboard Setup5-21I2C to PCI-X/PCI-E SlotsJumper Settings (J10/J11)Jumper Setting Defi nition J10: Closed J11:Closed Ena

Pagina 69 - 7-3 Advanced Settings

5-22SUPERSERVER 8015C-T User's Manual5-11 Onboard IndicatorsGLAN1/2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each p

Pagina 70 - IDE Confi guration Submenu

Chapter 5: Advanced Serverboard Setup5-235-12 Floppy, IDE, and SATA PortsUse the following information to connect the IDE hard disk drive cables.A re

Pagina 71 - PIO Mode

5-24SUPERSERVER 8015C-T User's ManualSATA PortsThere are no jumpers to confi g-ure the onboard SATA connec-tors. See the table on the right for pi

Pagina 72

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na

Pagina 73 - PCI/PnP Confi guration

6-2SUPERSERVER 8015C-T User's ManualFigure 6-1. Chassis: Front and Rear ViewsSystem Reset6-2 Control PanelThe control panel (located on the front

Pagina 74 - Advanced Chipset Settings

Chapter 6: Advanced Chassis Setup6-36-3 System FansSix 4-cm heavy duty counter-rotating fans provide the cooling for the 8015C-T. Each fan unit is act

Pagina 75

viSUPERSERVER 8015C-T User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Pagina 76

6-4SUPERSERVER 8015C-T User's ManualFigure 6-2. System Cooling Fans6-4 Drive Bay InstallationRemoving the Front BezelIf your system has a front b

Pagina 77

Chapter 6: Advanced Chassis Setup6-5Accessing the Drive BaysSATA Drives: Because of their hotswap capability, you do not need to access the inside of

Pagina 78 - USB Confi guration

6-6SUPERSERVER 8015C-T User's ManualFigure 6-4. Mounting a SATA Drive in a Carrier!Important: Regardless of how many SATA hard drives are in-stal

Pagina 79 - APCI Confi guration

Chapter 6: Advanced Chassis Setup6-7Figure 6-5. Removing a SATA Drive from the ServerSATA BackplaneThe SATA drives plug into a backplane that provides

Pagina 80 - APM Confi guration

6-8SUPERSERVER 8015C-T User's ManualDVD-ROM and Floppy Drive InstallationThe top cover of the chassis must be opened to gain full access to the D

Pagina 81

Chapter 6: Advanced Chassis Setup6-96-5 Power SupplyThe SuperServer 8015C-T has a single 1000 watt power supply, which is auto-switching capable. This

Pagina 82 - Hardware Health Confi guration

6-10SUPERSERVER 8015C-T User's ManualFigure 6-6. Removing/Replacing the Power Supply

Pagina 83 - MPS Confi guration

Chapter 7: BIOS7-1Chapter 7 BIOS7-1 IntroductionThis chapter describes the AMIBIOS Setup Utility for the X7QCE. The AMI ROM BIOS is stored in a Flash

Pagina 84 - Remote Access Confi guration

7-2SUPERSERVER 8015C-T User's Manual7-2 Main SetupWhen you fi rst enter the AMI BIOS Setup Utility, you will enter the Main setup screen. You can

Pagina 85 - Trusted Computing

Chapter 7: BIOS7-37-3 Advanced SettingsThe Advanced Settings screen and submenus are listed below:WarningWhen you fi rst enter the Advanced Setup scree

Pagina 86 - 7-4 Boot Confi guration

viiTable of ContentsInstalling the Server into the Rack ... 2-62-5 Checking the Server

Pagina 87 - Hard Disk Drive

7-4SUPERSERVER 8015C-T User's ManualIntel Virtualization Technology (Available when supported by the OS and the CPU.)Select Enabled to use the fe

Pagina 88 - CD/DVD Drives

Chapter 7: BIOS7-5TypeThis feature allows the user to select the type of device connected to the system. The options are Not Installed, Auto, CDROM, a

Pagina 89 - 7-5 Security Settings

7-6SUPERSERVER 8015C-T User's ManualDMA ModeSelect Auto to allow the BIOS to automatically detect the DMA mode. Use this value if the IDE disk dr

Pagina 90 - 7-6 Exit Options

Chapter 7: BIOS7-7Floppy Confi guration This option allows the user to confi gure the settings for the Floppy Drives installed in the system.Floppy A/

Pagina 91 - Load Fail-Safe Defaults

7-8SUPERSERVER 8015C-T User's ManualOffboard PCI/ISA IDE CardThis option allows the user to assign a PCI slot number to an off-board PCI/ISA IDE

Pagina 92

Chapter 7: BIOS7-9NorthBridge Confi gurationThis feature allows the user to confi gure the NorthBridge Chipset settings.Crystal Beach/DMAThis feature u

Pagina 93 - BIOS POST Messages

7-10SUPERSERVER 8015C-T User's ManualFBD Thermal Throttle ModeSelect Enabled to use the feature of closed-loop thermal throttling on a fully buff

Pagina 94

Chapter 7: BIOS7-11USB2 ControllerSelect Enabled to activate the onboard USB2 controller. The options are Enabled and Disabled.SLP_S4# Minimum Asserti

Pagina 95

7-12SUPERSERVER 8015C-T User's ManualEvent Log Confi gurationHighlight this item and press <Enter> to view the contents of the event log.Vi

Pagina 96

Chapter 7: BIOS7-13USB Mass Storage Device Confi gurationThis feature allows the user to confi gure the USB Mass Storage Device set-tings.USB Mass Stor

Pagina 97

viiiSUPERSERVER 8015C-T User's Manual5-12 Floppy, IDE, and SATA Ports ... 5

Pagina 98

7-14SUPERSERVER 8015C-T User's ManualChipset ACPI Confi gurationHigh Precision Event TimeSelect Enabled to activate the High Precision Event Time

Pagina 99 - BIOS POST Codes

Chapter 7: BIOS7-15Advanced Resume Event ControlResume On RingIf set to Enabled, the system will be "awakened" when the modem receives an in

Pagina 100 - POST Code Description

7-16SUPERSERVER 8015C-T User's ManualHardware Health Confi gurationThis feature allows the AMI BIOS to automatically display the status of the fo

Pagina 101

Chapter 7: BIOS7-17MPS Confi guration This section allows the user to confi gure the multiprocessors table.MPS RevisionThis feature allows the user to

Pagina 102

7-18SUPERSERVER 8015C-T User's ManualSMBIOS Confi gurationSMBIOS SMI SupportSelect Enabled to enable the function of SMBIOS SMI Wrapper support f

Pagina 103

Chapter 7: BIOS7-19Terminal TypeThis feature allows the user to select the target terminal type for Console Redirection.The options are ANSI, VT100, a

Pagina 104

7-20SUPERSERVER 8015C-T User's Manual7-4 Boot Confi gurationThis feature allows the user to confi gure the following items:Boot SettingsQuick Bo

Pagina 105 - HostRAID Setup Guidelines

Chapter 7: BIOS7-21Parity CheckingThis option allows the user to enable or disable SB IDCHK# and PCI SERR # Parity Checking. The options are Enabled a

Pagina 106 - The Intel Matrix Storage

7-22SUPERSERVER 8015C-T User's ManualRemovable DrivesThis feature allows the user to specify the boot sequence from available Remov-able Drives.

Pagina 107

Chapter 7: BIOS7-23Change Supervisor PasswordSelect this option and press <Enter> to access the Submenu, and then type in the password. Change U

Pagina 108

Chapter 1 Introduction1-1 OverviewThe SuperServer 8015C-T is a high-end server that is comprised of two main sub-systems: the SC818TQ-1000 1U server c

Pagina 109

7-24SUPERSERVER 8015C-T User's Manual7-6 Exit OptionsSelect the Exit tab from the AMIBIOS Setup Utility screen to enter the Exit BIOS Setup scree

Pagina 110

Chapter 7: BIOS7-25Load Fail-Safe DefaultsTo set this feature, select Load Fail-Safe Defaults from the Exit menu and press <Enter>. The Fail-Saf

Pagina 111

7-26SUPERSERVER 8015C-T User's ManualNotes

Pagina 112

A-1Appendix A: BIOS POST MessagesAppendix A BIOS POST MessagesDuring the Power-On Self-Test (POST), the BIOS will check for problems. If a prob-lem is

Pagina 113

A-2SUPERSERVER 8015C-T User's ManualSystem CMOS checksum bad - Default confi guration usedSystem CMOS has been corrupted or modifi ed incorrectly,

Pagina 114

A-3Appendix A: BIOS POST MessagesEISA CMOS not writeableServerBIOS2 test error: Cannot write to EISA CMOS.DMA Test FailedServerBIOS2 test error: Canno

Pagina 115 - System Specifi cations

A-4SUPERSERVER 8015C-T User's Manualnnnn kB Extended RAM PassedWhere nnnn is the amount of RAM in kilobytes successfully tested.nnnn Cache SRAM P

Pagina 116

A-5Appendix A: BIOS POST MessagesPS/2 Mouse:PS/2 mouse identifi ed.Run the I2O Confi guration UtilityOne or more unclaimed block storage devices have th

Pagina 117

A-6SUPERSERVER 8015C-T User's ManualNotes

Pagina 118

Appendix B: BIOS POST CodesB-1Appendix B BIOS POST CodesThis section lists the POST (Power On Self Test) codes for the Phoenix BIOS. POST codes are d