®SUPERSERVER® 7048R-C1RT4+7048R-C1R4+ SUPERUSER’S MANUAL 1.0
1-2SUPERSERVER 7048R-C1RT/7048R-C1R User's Manual1-2 Serverboard FeaturesThe SuperServer 7048R-C1RT4+/7048R-C1R4+ is built around the X10DRC-T4+
7-14SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualData ScramblingSelect Enabled to enable data scrambling to enhance system performance and
Chapter 7: BIOS7-15Patrol ScrubPatrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected on a memory module and
7-16SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualXHCI Hand-OffThis is a work-around solution for operating systems that do not support XHCI
Chapter 7: BIOS7-17SATA CongurationWhen this submenu is selected, AMI BIOS automatically detects the presence of the SATA devices that are supported
7-18SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual*If the item above "Congure SATA as" is set to IDE, the following items will dis
Chapter 7: BIOS7-19Port 0 ~ Port 5 Spin Up DeviceOn an edge detect from 0 to 1, set this item to allow the PCH to start a COMRE-SET initialization to
7-20SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualsSATA Port 0 ~ Port 3 Spin Up DeviceOn an edge detect from 0 to 1, set this item to allow t
Chapter 7: BIOS7-21sSATA Port 0~ Port 3This item displays the information detected on the installed sSATA drives on the particular sSATA port.•Model
7-22SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualPCIe/PCI/PnP CongurationThe following PCI information will be displayed:•PCI Bus Driver
Chapter 7: BIOS7-23ASPM SupportUse this item to set the Active State Power Management (ASPM) level for a PCI-E device. Select Auto for the system BIOS
1-3Chapter 1: IntroductionRear I/O PortsThe I/O ports include two COM ports (one Fast UART 16550 external serial port, one serial port header), two VG
7-24SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualSuper IO Conguration Super IO Chip AST2400Serial Port 1 Conguration/Serial Port 2 Cong
Chapter 7: BIOS7-25*If the item above set to Enabled, the following items will become available for conguration:COM1 Console Redirectio
7-26SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualVT-UTF8 Combo Key SupportSelect Enabled to enable VT-UTF8 Combination Key support for ANSI/
Chapter 7: BIOS7-27SOL/COM2 Console Redirection SettingsUse this feature to specify how the host computer will exchange data with the client computer
7-28SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualVT-UTF8 Combo Key SupportSelect Enabled to enable VT-UTF8 Combination Key support for ANSI/
Chapter 7: BIOS7-29Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS)The submenu allows the user to congure Console R
7-30SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualFlow ControlUse this item to set the ow control for Console Redirection to pre
Chapter 7: BIOS7-31Intel TXT (LT-SX) CongurationThis submenu allows the user to congure the following TXT settings.TXT Support Select Enabled to en
7-32SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual7-4 Event LogsUse this feature to congure Event Log settings.Change SMBIOS Event Log Se
Chapter 7: BIOS7-33Erasing SettingsErase Event LogSelect Yes to erase all error events in the SMBIOS (System Management BIOS) log before an event logg
1-4SUPERSERVER 7048R-C1RT/7048R-C1R User's ManualFigure 1-1. Chipset Block DiagramNote: This is a general block diagram. Please see Chapter 5 fo
7-34SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual7-5 IPMIUse this feature to congure Intelligent Platform Management Interface (
Chapter 7: BIOS7-35When SEL is FullThis feature allows the user to determine what the AMI BIOS should do when the system event log is full. Select Era
7-36SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual7-6 Security SettingsThis menu allows the user to congure the following security
Chapter 7: BIOS7-377-7 Boot SettingsUse this feature to congure Boot Settings:Boot CongurationSetup Prompt TimeoutUse this item to indicate how man
7-38SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualDelete Boot OptionUse this item to select a boot device to delete from the boot priority l
Chapter 7: BIOS7-397-8 Save & ExitSelect the Save & Exit tab from the BIOS setup screen to congure the settings below.Discard Cha
7-40SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualSave As User DefaultsSelect this item and press <Enter> to save the current BIOS sett
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time th
A-2SUPERSERVER 7048R-C1R4+/7048R-C1RT4+ User's ManualNotes
B-1Appendix B: System SpecicationsAppendix B System SpecicationsProcessorsSingle or dual Intel® E5-2600 (v3) Series processors in Socket R, LGA 20
1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408
B-2SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualExpansion SlotsTwo PCI-E 3.0 x16 slots, three PCI-E 3.0 x8 slots and one PCI-E 2.0 x4 (in x8
B-3Appendix B: System SpecicationsPower Supply7048R-C1RT4+Rated Output Power: 1000W (Part# PWS-1K03A-1R)Rated Output Voltages: +12V (66.7A @ 800W, 83
B-4SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be u
1-6SUPERSERVER 7048R-C1RT/7048R-C1R User's ManualNotes
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 7048
2-2SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual•This product is not suitable for use with visual display work place devices acccording to
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
2-4SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual2-5 Installing the System into a RackThis section provides information on installing the sy
Chapter 2: Server Installation2-5Installing the Chassis RailsYou will need to remove the top cover and the feet to add rack rails to the chassis. Firs
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur
2-6SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualInstalling the Rack RailsDetermine where you want to place the SuperServer 7048R-C1RT4+/7048
Chapter 2: Server Installation2-7Figure 2-4. Installing the Server into a RackInstalling the Server into the RackYou should now have rails attached t
2-8SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualNotes
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThe control panel on the 7048R-C1RT4+/7048R-C1R4+ has several LEDs and two butto
3-2SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC745 chassis has six L
Chapter 3: System Interface3-3Information LEDThis LED will be solid blue when the UID function has been activated. When this LED ashes red, it in
3-4SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualNotes
4-1Chapter 4: Warning Statements for AC SystemsChapter 4 Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe
4-2SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie benden sich
4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta
4-4SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualInstallation Instructions Warning!Read the installation instructions before connecting the s
4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over
4-6SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualPower Disconnection Warning 電源切断の警告システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセスするには、システムの電源はすべての
4-7Chapter 4: Warning Statements for AC Systems¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico qu
4-8SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualEquipment Installation機器の設置トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可されています。 Warning!Only train
4-9Chapter 4: Warning Statements for AC Systemsアクセス制限区域このユニットは、アクセス制限区域に設置されることを想定しています。アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いてのみ出入りが可能です。 Warning!Thi
4-10SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualBattery Handling Warning!There is the danger of explosion if the battery is replaced incorr
4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur
4-12SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualWarnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Ein
4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltageバックプレーンの電圧システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。修理する際には注意ください。警告当系统正在进行时,背板上有很危险的电压或能
SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X10DRC-T
4-14SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualComply with Local and National Electrical Codes Warning!Installation of the equipment must
4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national
4-16SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualWaarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenst
4-17Chapter 4: Warning Statements for AC SystemsWarnungDie Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halt
4-18SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual Warning!When installing the product, use the provided or designated connection cables, pow
4-19Chapter 4: Warning Statements for AC SystemsAttention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné
4-20SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualNotes
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install processors and heatsin
5-2SUPERSERVER 7048R-C1R(T)4+ User's Manual5-2 Processor and Heatsink InstallationNotes: •Always remove the power cord before adding, removing
Chapter 5: Advanced Serverboard Setup5-33. With the second lever fully retracted, gently push down on the "Open 1st" lever to loosen the lo
NotesPrefacev
5-4SUPERSERVER 7048R-C1R(T)4+ User's Manual8. Make sure the locking mechanism on the "Close 1st" lever catches the lip of the load pla
Chapter 5: Advanced Serverboard Setup5-5Installing a Passive CPU Heatsink1. Do not apply any thermal grease to the heatsink or the CPU die; the requi
5-6SUPERSERVER 7048R-C1R(T)4+ User's Manual5-3 Connecting CablesNow that the processors are installed, the next step is to connect the cables to
Chapter 5: Advanced Serverboard Setup5-75-4 I/O PortsFigure 5-2 shows the I/O ports on the rear of the system.Figure 5-2. Rear Panel I/O PortsLAN Por
5-8SUPERSERVER 7048R-C1R(T)4+ User's Manual5-5 Installing MemoryNote: Check the Supermicro web site for recommended memory modules. CAUTION Exer
Chapter 5: Advanced Serverboard Setup5-9Memory SupportThe server features 24 DIMM slots that can support up to 1536GB of Load Reduction (LRDIMM) or up
5-10SUPERSERVER 7048R-C1R(T)4+ User's ManualCaution: For the memory to work properly, install DIMMs of the same type and speed. Mixing of DIMMs
Chapter 5: Advanced Serverboard Setup5-11Figure 5-4. X10DRC-T4+/LN4+ Layout5-6 Serverboard DetailsIPMI CODESAS CODESAN MACT-SGPIO1T-SGPIO2JD1JS39LED
5-12SUPERSERVER 7048R-C1R(T)4+ User's ManualServerboard Quick ReferenceJumpersJumper Description Default SettingJBT1 Clear CMOS See Section 5-8JI
Chapter 5: Advanced Serverboard Setup5-13Warning: To avoid damaging the power supply or the serverboard, be sure to use a power supply that contains a
viTable of ContentsChapter 1 Introduction1-1 Overview ...
5-14SUPERSERVER 7048R-C1R(T)4+ User's Manual5-7 Connector DenitionsPower ConnectorsA 24-pin main power supply connector (J24), and two 8-pin CP
Chapter 5: Advanced Serverboard Setup5-15Power ButtonOH/Fan Fail/PWR Fail LED)1NIC1 Link LEDReset Button2Power Fail LEDHDD LEDFP PWRLEDResetPWR3.3 VUI
5-16SUPERSERVER 7048R-C1R(T)4+ User's ManualPower Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on
Chapter 5: Advanced Serverboard Setup5-17Power LED The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table on the right for p
5-18SUPERSERVER 7048R-C1R(T)4+ User's ManualGLAN/10G-LAN (TLAN) Ports & IPMI_LAN PortFour Ethernet ports (LAN1/2, LAN3/4) are located on the
Chapter 5: Advanced Serverboard Setup5-19Chassis Intrusion A Chassis Intrusion header is located at JL1. Attach an appropriate cable from the chassis
5-20SUPERSERVER 7048R-C1R(T)4+ User's ManualTPM Header/Port 80A Trusted Platform Module/Port 80 header is located at JTPM1 to provide TPM support
Chapter 5: Advanced Serverboard Setup5-21T-SGPIO1/2 & S-SGPIO1 HeadersThree SGPIO (Serial Link Gen-eral Purpose Input/Output) headers are located
5-22SUPERSERVER 7048R-C1R(T)4+ User's Manual5-8 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be
Chapter 5: Advanced Serverboard Setup5-23VGA Enable/DisableJPG1 allows you to enable or disable the onboard VGA port. The default position is on pins
viiPower ... 3-1Reset ...
5-24SUPERSERVER 7048R-C1R(T)4+ User's Manual5-9 Onboard IndicatorsI2C Bus to PCI-Exp. SlotsUse Jumpers JI2C1 and JI2C2 to con-nect the System Ma
Chapter 5: Advanced Serverboard Setup5-25Onboard PWR LED Indicator LED StatesColor/State Denition Off System Power OffGreen: On System Power O
5-26SUPERSERVER 7048R-C1R(T)4+ User's ManualSATA Port Pin DenitionsPin # Denition 1 Ground2 TXP3 TXN4 Ground5 RXN6 RXP7 GroundNot
Chapter 5: Advanced Serverboard Setup5-275-11 Installing SoftwareThe Supermicro ftp site contains drivers and utilities for your system at ftp://ftp.
5-28SUPERSERVER 7048R-C1R(T)4+ User's ManualSuperDoctor® 5The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based
Chapter 5: Advanced Serverboard Setup5-295-12 Onboard BatteryPlease handle used batteries carefully. Do not damage the battery in any way; a damaged
5-30SUPERSERVER 7048R-C1R(T)4+ User's ManualNotes
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform simple
6-2SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualFigure 6-1. Chassis Front ViewSystem ResetMain Power One 5.25" Drive Bay USB PortsEncl
Chapter 6: Advanced Chassis Setup6-36-2 Front Control PanelThe front control panel must be connected to the JF1 connector on the serverboard to provi
viiiMemory Support ... 5-9Processor & Memory Module Pop
6-4SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual6-3 System FansThree 8-cm chassis cooling fans (located in the center of the chassis) provi
Chapter 6: Advanced Chassis Setup6-5Figure 6-4. Removing the Air ShroudFigure 6-3. Removing a Chassis FanRemoving the Air ShroudUnder most circumsta
6-6SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualInstalling/Removing Hard Drives1. To remove a carrier, rst open the front bezel.2. Push t
Chapter 6: Advanced Chassis Setup6-7Figure 6-6. Mounting a Drive in a CarrierWarning: Use extreme caution when working around the SAS/SATA backplane.
6-8SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualInstalling Components in the 5.25" Drive BaysThe 7048R-C1RT4+/7048R-C1R4+ has one 5.25&
Chapter 6: Advanced Chassis Setup6-9Figure 6-7. Rotating the Mobile RackEnclosure Release LeverMobile RackMobile Rack EnclosureNote: image above is f
6-10SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual6-5 Power SupplyThe SuperServer 7048R-C1RT4+ has a redundant, hot-plug 1000 watt power sup
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS setup utility for the X10DRC/i-LN4+/-T4+. The ROM BIOS is sto
7-2SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine i
Chapter 7: BIOS7-3The following Main menu items will be displayed:System Date/System Time Use this option to change the system date and time. Highligh
Chapter 1 Introduction1-1 OverviewThe SuperServer 7048R-C1RT4+/7048R-C1R4+ is a high-end server comprised of two main subsystems: the SC745TQ-R1K03B
7-4SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual7-3 Advanced Setup CongurationsUse the arrow keys to select Advanced setup and press <
Chapter 7: BIOS7-5Wait For 'F1' If ErrorSelect Enabled to force the system to wait until the <F1> key is pressed if an error occurs. T
7-6SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualCPU CongurationThis submenu displays the following CPU information as detected by the BIOS
Chapter 7: BIOS7-7illegal codes to overwhelm the processor to damage the system during an attack. The options are Enable and Disable. (Refer to Intel&
7-8SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualAES-NISelect Enable to use the Intel Advanced Encryption Standard (AES) New Instruc-tions (N
Chapter 7: BIOS7-9 CPU C State Control (Available when Power Technology is set to Custom)Package C State limitUse this item to set the limit on the C
7-10SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualChipset CongurationWarning! Please set the correct settings for the items below. A
Chapter 7: BIOS7-11II01 PORT 3A Link SpeedThis item congures the link speed of a PCI-E port specied by the user. The options are Gen 1 (Generat
7-12SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualIOAT (Intel® IO Acceleration) CongurationEnable IOATSelect Enable to enable Intel I/OAT (
Chapter 7: BIOS7-13•Current QPI Link Frequency•QPI Global MMIO Low Base/Limit•QPI Global MMIO High Base/Limit•QPI PCIe Conguration Base/SizeLink