Supermicro SuperServer 7048R-C1R4+ Manual de usuario

Busca en linea o descarga Manual de usuario para Barebones Servidor Supermicro SuperServer 7048R-C1R4+. Supermicro SuperServer 7048R-C1R4+ Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 132
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - SUPER

®SUPERSERVER® 7048R-C1RT4+7048R-C1R4+ SUPERUSER’S MANUAL 1.0

Pagina 2 - Release Date: October 9, 2014

1-2SUPERSERVER 7048R-C1RT/7048R-C1R User's Manual1-2 Serverboard FeaturesThe SuperServer 7048R-C1RT4+/7048R-C1R4+ is built around the X10DRC-T4+

Pagina 3 - Manual Organization

7-14SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualData ScramblingSelect Enabled to enable data scrambling to enhance system performance and

Pagina 4

Chapter 7: BIOS7-15Patrol ScrubPatrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected on a memory module and

Pagina 5

7-16SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualXHCI Hand-OffThis is a work-around solution for operating systems that do not support XHCI

Pagina 6 - Table of Contents

Chapter 7: BIOS7-17SATA CongurationWhen this submenu is selected, AMI BIOS automatically detects the presence of the SATA devices that are supported

Pagina 7

7-18SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual*If the item above "Congure SATA as" is set to IDE, the following items will dis

Pagina 8

Chapter 7: BIOS7-19Port 0 ~ Port 5 Spin Up DeviceOn an edge detect from 0 to 1, set this item to allow the PCH to start a COMRE-SET initialization to

Pagina 9 - Introduction

7-20SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualsSATA Port 0 ~ Port 3 Spin Up DeviceOn an edge detect from 0 to 1, set this item to allow t

Pagina 10 - 1-2 Serverboard Features

Chapter 7: BIOS7-21sSATA Port 0~ Port 3This item displays the information detected on the installed sSATA drives on the particular sSATA port.•Model

Pagina 11 - 1-3 Server Chassis Features

7-22SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualPCIe/PCI/PnP CongurationThe following PCI information will be displayed:•PCI Bus Driver

Pagina 12

Chapter 7: BIOS7-23ASPM SupportUse this item to set the Active State Power Management (ASPM) level for a PCI-E device. Select Auto for the system BIOS

Pagina 13 - 1-4 Contacting Supermicro

1-3Chapter 1: IntroductionRear I/O PortsThe I/O ports include two COM ports (one Fast UART 16550 external serial port, one serial port header), two VG

Pagina 14

7-24SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualSuper IO Conguration Super IO Chip AST2400Serial Port 1 Conguration/Serial Port 2 Cong

Pagina 15 - Server Installation

Chapter 7: BIOS7-25*If the item above set to Enabled, the following items will become available for conguration:COM1 Console Redirectio

Pagina 16 - 2-4 Warnings and Precautions

7-26SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualVT-UTF8 Combo Key SupportSelect Enabled to enable VT-UTF8 Combination Key support for ANSI/

Pagina 17 - Rack Mounting Considerations

Chapter 7: BIOS7-27SOL/COM2 Console Redirection SettingsUse this feature to specify how the host computer will exchange data with the client computer

Pagina 18 - Rail brackets

7-28SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualVT-UTF8 Combo Key SupportSelect Enabled to enable VT-UTF8 Combination Key support for ANSI/

Pagina 19 - Installing the Chassis Rails

Chapter 7: BIOS7-29Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS)The submenu allows the user to congure Console R

Pagina 20 - Installing the Rack Rails

7-30SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualFlow ControlUse this item to set the ow control for Console Redirection to pre

Pagina 21

Chapter 7: BIOS7-31Intel TXT (LT-SX) CongurationThis submenu allows the user to congure the following TXT settings.TXT Support Select Enabled to en

Pagina 22

7-32SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual7-4 Event LogsUse this feature to congure Event Log settings.Change SMBIOS Event Log Se

Pagina 23 - System Interface

Chapter 7: BIOS7-33Erasing SettingsErase Event LogSelect Yes to erase all error events in the SMBIOS (System Management BIOS) log before an event logg

Pagina 24 - 3-3 Control Panel LEDs

1-4SUPERSERVER 7048R-C1RT/7048R-C1R User's ManualFigure 1-1. Chipset Block DiagramNote: This is a general block diagram. Please see Chapter 5 fo

Pagina 25 - 3-4 Drive Carrier LEDs

7-34SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual7-5 IPMIUse this feature to congure Intelligent Platform Management Interface (

Pagina 26

Chapter 7: BIOS7-35When SEL is FullThis feature allows the user to determine what the AMI BIOS should do when the system event log is full. Select Era

Pagina 27 - Chapter 4

7-36SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual7-6 Security SettingsThis menu allows the user to congure the following security

Pagina 28

Chapter 7: BIOS7-377-7 Boot SettingsUse this feature to congure Boot Settings:Boot CongurationSetup Prompt TimeoutUse this item to indicate how man

Pagina 29

7-38SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualDelete Boot OptionUse this item to select a boot device to delete from the boot priority l

Pagina 30 - Installation Instructions

Chapter 7: BIOS7-397-8 Save & ExitSelect the Save & Exit tab from the BIOS setup screen to congure the settings below.Discard Cha

Pagina 31 - Circuit Breaker

7-40SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualSave As User DefaultsSelect this item and press <Enter> to save the current BIOS sett

Pagina 32 - Power Disconnection Warning

A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time th

Pagina 33 - ילמשח קותינ ינפמ הרהזא

A-2SUPERSERVER 7048R-C1R4+/7048R-C1RT4+ User's ManualNotes

Pagina 34 - Equipment Installation

B-1Appendix B: System SpecicationsAppendix B System SpecicationsProcessorsSingle or dual Intel® E5-2600 (v3) Series processors in Socket R, LGA 20

Pagina 35 - Restricted Area

1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408

Pagina 36 - Battery Handling

B-2SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualExpansion SlotsTwo PCI-E 3.0 x16 slots, three PCI-E 3.0 x8 slots and one PCI-E 2.0 x4 (in x8

Pagina 37

B-3Appendix B: System SpecicationsPower Supply7048R-C1RT4+Rated Output Power: 1000W (Part# PWS-1K03A-1R)Rated Output Voltages: +12V (66.7A @ 800W, 83

Pagina 38 - Redundant Power Supplies

B-4SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be u

Pagina 39 - Backplane Voltage

1-6SUPERSERVER 7048R-C1RT/7048R-C1R User's ManualNotes

Pagina 40

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 7048

Pagina 41 - Product Disposal

2-2SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual•This product is not suitable for use with visual display work place devices acccording to

Pagina 42 - Hot Swap Fan Warning

Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Pagina 43

2-4SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual2-5 Installing the System into a RackThis section provides information on installing the sy

Pagina 44 - Power Cable and AC Adapter

Chapter 2: Server Installation2-5Installing the Chassis RailsYou will need to remove the top cover and the feet to add rack rails to the chassis. Firs

Pagina 45 - (UL/CSA  )

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur

Pagina 46

2-6SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualInstalling the Rack RailsDetermine where you want to place the SuperServer 7048R-C1RT4+/7048

Pagina 47 - Advanced Serverboard Setup

Chapter 2: Server Installation2-7Figure 2-4. Installing the Server into a RackInstalling the Server into the RackYou should now have rails attached t

Pagina 48 - OPEN 1st

2-8SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualNotes

Pagina 49 - IMPORTANT!

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThe control panel on the 7048R-C1RT4+/7048R-C1R4+ has several LEDs and two butto

Pagina 50

3-2SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC745 chassis has six L

Pagina 51

Chapter 3: System Interface3-3Information LEDThis LED will be solid blue when the UID function has been activated. When this LED ashes red, it in

Pagina 52 - 5-3 Connecting Cables

3-4SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualNotes

Pagina 53 - 5-4 I/O Ports

4-1Chapter 4: Warning Statements for AC SystemsChapter 4 Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe

Pagina 54 - 5-5 Installing Memory

4-2SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie benden sich

Pagina 55 - Memory Support

4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확

Pagina 56 - INTEL CONFIDENTIAL

iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta

Pagina 57 - TPM/PORT80

4-4SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualInstallation Instructions Warning!Read the installation instructions before connecting the s

Pagina 58 - Serverboard Quick Reference

4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over

Pagina 59

4-6SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualPower Disconnection Warning 電源切断の警告システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセスするには、システムの電源はすべての

Pagina 60 - 5-7 Connector Denitions

4-7Chapter 4: Warning Statements for AC Systems¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico qu

Pagina 61 - Front Control Panel

4-8SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualEquipment Installation機器の設置トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可されています。 Warning!Only train

Pagina 62

4-9Chapter 4: Warning Statements for AC Systemsアクセス制限区域このユニットは、アクセス制限区域に設置されることを想定しています。アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いてのみ出入りが可能です。 Warning!Thi

Pagina 63 - Rear I/O Shield

4-10SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualBattery Handling Warning!There is the danger of explosion if the battery is replaced incorr

Pagina 64 - UID LED Status

4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur

Pagina 65 - Other Connectors

4-12SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualWarnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Ein

Pagina 66

4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltageバックプレーンの電圧システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。修理する際には注意ください。警告当系统正在进行时,背板上有很危险的电压或能

Pagina 67

SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X10DRC-T

Pagina 68 - 2-3 Disabled

4-14SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualComply with Local and National Electrical Codes Warning!Installation of the equipment must

Pagina 69

4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national

Pagina 70 - 5-9 Onboard Indicators

4-16SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualWaarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenst

Pagina 71

4-17Chapter 4: Warning Statements for AC SystemsWarnungDie Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halt

Pagina 72 - 5-10 SATA/SAS Connections

4-18SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual Warning!When installing the product, use the provided or designated connection cables, pow

Pagina 73 - 5-11 Installing Software

4-19Chapter 4: Warning Statements for AC SystemsAttention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné

Pagina 74 - SuperDoctor® 5

4-20SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualNotes

Pagina 75 - 5-12 Onboard Battery

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install processors and heatsin

Pagina 76

5-2SUPERSERVER 7048R-C1R(T)4+ User's Manual5-2 Processor and Heatsink InstallationNotes: •Always remove the power cord before adding, removing

Pagina 77 - Advanced Chassis Setup

Chapter 5: Advanced Serverboard Setup5-33. With the second lever fully retracted, gently push down on the "Open 1st" lever to loosen the lo

Pagina 78

NotesPrefacev

Pagina 79 - 6-2 Front Control Panel

5-4SUPERSERVER 7048R-C1R(T)4+ User's Manual8. Make sure the locking mechanism on the "Close 1st" lever catches the lip of the load pla

Pagina 80 - 6-3 System Fans

Chapter 5: Advanced Serverboard Setup5-5Installing a Passive CPU Heatsink1. Do not apply any thermal grease to the heatsink or the CPU die; the requi

Pagina 81

5-6SUPERSERVER 7048R-C1R(T)4+ User's Manual5-3 Connecting CablesNow that the processors are installed, the next step is to connect the cables to

Pagina 82 - 6-4 Drive Bay Installation

Chapter 5: Advanced Serverboard Setup5-75-4 I/O PortsFigure 5-2 shows the I/O ports on the rear of the system.Figure 5-2. Rear Panel I/O PortsLAN Por

Pagina 83 - SAS/SATA Backplane

5-8SUPERSERVER 7048R-C1R(T)4+ User's Manual5-5 Installing MemoryNote: Check the Supermicro web site for recommended memory modules. CAUTION Exer

Pagina 84 - Mobile Rack (Storage Module)

Chapter 5: Advanced Serverboard Setup5-9Memory SupportThe server features 24 DIMM slots that can support up to 1536GB of Load Reduction (LRDIMM) or up

Pagina 85 - Mobile Rack Enclosure

5-10SUPERSERVER 7048R-C1R(T)4+ User's ManualCaution: For the memory to work properly, install DIMMs of the same type and speed. Mixing of DIMMs

Pagina 86 - 6-5 Power Supply

Chapter 5: Advanced Serverboard Setup5-11Figure 5-4. X10DRC-T4+/LN4+ Layout5-6 Serverboard DetailsIPMI CODESAS CODESAN MACT-SGPIO1T-SGPIO2JD1JS39LED

Pagina 87 - Chapter 7

5-12SUPERSERVER 7048R-C1R(T)4+ User's ManualServerboard Quick ReferenceJumpersJumper Description Default SettingJBT1 Clear CMOS See Section 5-8JI

Pagina 88 - 7-2 Main Setup

Chapter 5: Advanced Serverboard Setup5-13Warning: To avoid damaging the power supply or the serverboard, be sure to use a power supply that contains a

Pagina 89

viTable of ContentsChapter 1 Introduction1-1 Overview ...

Pagina 90 - Boot Feature

5-14SUPERSERVER 7048R-C1R(T)4+ User's Manual5-7 Connector DenitionsPower ConnectorsA 24-pin main power supply connector (J24), and two 8-pin CP

Pagina 91 - Power Conguration

Chapter 5: Advanced Serverboard Setup5-15Power ButtonOH/Fan Fail/PWR Fail LED)1NIC1 Link LEDReset Button2Power Fail LEDHDD LEDFP PWRLEDResetPWR3.3 VUI

Pagina 92 - CPU Conguration

5-16SUPERSERVER 7048R-C1R(T)4+ User's ManualPower Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on

Pagina 93

Chapter 5: Advanced Serverboard Setup5-17Power LED The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table on the right for p

Pagina 94

5-18SUPERSERVER 7048R-C1R(T)4+ User's ManualGLAN/10G-LAN (TLAN) Ports & IPMI_LAN PortFour Ethernet ports (LAN1/2, LAN3/4) are located on the

Pagina 95

Chapter 5: Advanced Serverboard Setup5-19Chassis Intrusion A Chassis Intrusion header is located at JL1. Attach an appropriate cable from the chassis

Pagina 96 - IIO1 Conguration

5-20SUPERSERVER 7048R-C1R(T)4+ User's ManualTPM Header/Port 80A Trusted Platform Module/Port 80 header is located at JTPM1 to provide TPM support

Pagina 97 - IIO2 Conguration

Chapter 5: Advanced Serverboard Setup5-21T-SGPIO1/2 & S-SGPIO1 HeadersThree SGPIO (Serial Link Gen-eral Purpose Input/Output) headers are located

Pagina 98 - •Current QPI Link Speed

5-22SUPERSERVER 7048R-C1R(T)4+ User's Manual5-8 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be

Pagina 99 - •Current QPI Link Frequency

Chapter 5: Advanced Serverboard Setup5-23VGA Enable/DisableJPG1 allows you to enable or disable the onboard VGA port. The default position is on pins

Pagina 100 - DIMM Information

viiPower ... 3-1Reset ...

Pagina 101 - •USB Devices

5-24SUPERSERVER 7048R-C1R(T)4+ User's Manual5-9 Onboard IndicatorsI2C Bus to PCI-Exp. SlotsUse Jumpers JI2C1 and JI2C2 to con-nect the System Ma

Pagina 102

Chapter 5: Advanced Serverboard Setup5-25Onboard PWR LED Indicator LED StatesColor/State Denition Off System Power OffGreen: On System Power O

Pagina 103 - SATA Conguration

5-26SUPERSERVER 7048R-C1R(T)4+ User's ManualSATA Port Pin DenitionsPin # Denition 1 Ground2 TXP3 TXN4 Ground5 RXN6 RXP7 GroundNot

Pagina 104

Chapter 5: Advanced Serverboard Setup5-275-11 Installing SoftwareThe Supermicro ftp site contains drivers and utilities for your system at ftp://ftp.

Pagina 105

5-28SUPERSERVER 7048R-C1R(T)4+ User's ManualSuperDoctor® 5The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based

Pagina 106

Chapter 5: Advanced Serverboard Setup5-295-12 Onboard BatteryPlease handle used batteries carefully. Do not damage the battery in any way; a damaged

Pagina 107

5-30SUPERSERVER 7048R-C1R(T)4+ User's ManualNotes

Pagina 108 - •PCI Device Common Settings

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform simple

Pagina 109

6-2SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualFigure 6-1. Chassis Front ViewSystem ResetMain Power One 5.25" Drive Bay USB PortsEncl

Pagina 110 - Super IO Conguration

Chapter 6: Advanced Chassis Setup6-36-2 Front Control PanelThe front control panel must be connected to the JF1 connector on the serverboard to provi

Pagina 111

viiiMemory Support ... 5-9Processor & Memory Module Pop

Pagina 112

6-4SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual6-3 System FansThree 8-cm chassis cooling fans (located in the center of the chassis) provi

Pagina 113

Chapter 6: Advanced Chassis Setup6-5Figure 6-4. Removing the Air ShroudFigure 6-3. Removing a Chassis FanRemoving the Air ShroudUnder most circumsta

Pagina 114

6-6SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualInstalling/Removing Hard Drives1. To remove a carrier, rst open the front bezel.2. Push t

Pagina 115

Chapter 6: Advanced Chassis Setup6-7Figure 6-6. Mounting a Drive in a CarrierWarning: Use extreme caution when working around the SAS/SATA backplane.

Pagina 116

6-8SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualInstalling Components in the 5.25" Drive BaysThe 7048R-C1RT4+/7048R-C1R4+ has one 5.25&

Pagina 117 - ACPI Settings

Chapter 6: Advanced Chassis Setup6-9Figure 6-7. Rotating the Mobile RackEnclosure Release LeverMobile RackMobile Rack EnclosureNote: image above is f

Pagina 118 - 7-4 Event Logs

6-10SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual6-5 Power SupplyThe SuperServer 7048R-C1RT4+ has a redundant, hot-plug 1000 watt power sup

Pagina 119 - View SMBIOS Event Log

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS setup utility for the X10DRC/i-LN4+/-T4+. The ROM BIOS is sto

Pagina 120 - 7-5 IPMI

7-2SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine i

Pagina 121 - •IPMI Network Link Status

Chapter 7: BIOS7-3The following Main menu items will be displayed:System Date/System Time Use this option to change the system date and time. Highligh

Pagina 122 - 7-6 Security Settings

Chapter 1 Introduction1-1 OverviewThe SuperServer 7048R-C1RT4+/7048R-C1R4+ is a high-end server comprised of two main subsystems: the SC745TQ-R1K03B

Pagina 123 - 7-7 Boot Settings

7-4SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual7-3 Advanced Setup CongurationsUse the arrow keys to select Advanced setup and press <

Pagina 124 - •UEFI Boot Order #1

Chapter 7: BIOS7-5Wait For 'F1' If ErrorSelect Enabled to force the system to wait until the <F1> key is pressed if an error occurs. T

Pagina 125 - 7-8 Save & Exit

7-6SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualCPU CongurationThis submenu displays the following CPU information as detected by the BIOS

Pagina 126

Chapter 7: BIOS7-7illegal codes to overwhelm the processor to damage the system during an attack. The options are Enable and Disable. (Refer to Intel&

Pagina 127 - BIOS Error Beep Codes

7-8SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualAES-NISelect Enable to use the Intel Advanced Encryption Standard (AES) New Instruc-tions (N

Pagina 128

Chapter 7: BIOS7-9 CPU C State Control (Available when Power Technology is set to Custom)Package C State limitUse this item to set the limit on the C

Pagina 129 - System Specications

7-10SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualChipset CongurationWarning! Please set the correct settings for the items below. A

Pagina 130

Chapter 7: BIOS7-11II01 PORT 3A Link SpeedThis item congures the link speed of a PCI-E port specied by the user. The options are Gen 1 (Generat

Pagina 131 - Regulatory Compliance

7-12SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's ManualIOAT (Intel® IO Acceleration) CongurationEnable IOATSelect Enable to enable Intel I/OAT (

Pagina 132

Chapter 7: BIOS7-13•Current QPI Link Frequency•QPI Global MMIO Low Base/Limit•QPI Global MMIO High Base/Limit•QPI PCIe Conguration Base/SizeLink

Comentarios a estos manuales