
2-6
SUPERSERVER 7048R-C1RT4+/7048R-C1R4+ User's Manual
Installing the Rack Rails
Determine where you want to place the SuperServer 7048R-C1RT4+/7048R-C1R4+
in the rack. (See Rack and Server Precautions in Section 2-3.) Position the xed
rack rail/sliding rail guide assemblies at the desired location in the rack, keeping
the sliding rail guide facing the inside of the rack. Screw the assembly securely to
the rack using the brackets provided. Attach the other assembly to the other side
of the rack, making sure both are at the exact same height and with the rail guides
facing inward.
Figure 2-3. Installing the Rails to the Chassis
Warning: Do not pick up the server with the front handles. They are de-
signed to pull the system from a rack only.
Warning: Stability hazard. The rack stabilizing mechanism must be in
place, or the rack must be bolted to the oor before you slide the unit out
for servicing. Failure to stabilize the rack can cause the rack to tip over.
Warning: Slide rail mounted equipment is not to be used as a shelf or a
work space.
Comentarios a estos manuales