Supermicro SYS-8015C-TB Ficha de datos Pagina 49

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 118
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 48
Chapter 5: Advanced Serverboard Setup
5-17
Power SMB (I
2
C) Connector
Power SMB (I
2
C) connector, located
at J13, monitors the status of the
power supply, fan and system tem-
perature. See the table on the right
for pin defi nitions.
PWR SMB Header
Pin Defi nitions (J13)
Pin# Defi nition
1 Clock
2 Data
3 PWR Fail (Input from PS to MB)
4 Ground
5 +3.3V
Alarm Reset
If three power supplies are installed,
the system can notify you when any of
the three power modules fail. Connect
JAR to a micro-switch to enable you
to turn off the alarm that is activated
when a power module fails. See the
table on the right for pin defi nitions.
Alarm Reset Header
Pin Defi nitions (JAR)
Pin Setting Defi nition
Pin 1 Ground
Pin 2 +5V
Overheat LED/Fan Fail (JOH1)
The JOH1 header is used to connect
an LED to provide warning of chassis
overheating. This LED will blink to in-
dicate a fan failure. Refer to the table
on right for pin defi nitions.
Overheat LED
Pin Defi nitions (JOH1)
Pin# Defi nition
1 5vDC
2 OH Active
OH/Fan Fail LED
States
State Message
Solid Overheat
Blinking Fan Fail
Compact Flash Card PWR
Connector
A Compact Flash Card Power Con-
nector is located at JWF1. For the
Compact Flash Card to work properly,
you will need to enable with JCF1 and
connect a Compact Flash Card power
cable to JWF1 fi rst.
Compact Flash Card PWR
Connector (JWF1)
Jumper Defi nition
On Compact Flash
Power On
Off Compact Flash
Power Off
Vista de pagina 48