4-3
Chapter 4: System Interface
Power: Indicates power is being supplied to the system's power supply units. This
LED should normally be illuminated when the system is operating.
HDD: Indicates activity in the SAS/SATA drive and/or DVD-ROM drive activity
when ashing.
NIC1: Indicates network activity on GLAN1 when ashing.
NIC2: Indicates network activity on GLAN2 when ashing.
Informational LED
Status Description
Continuously on and red
An overheat condition has occured.
(This may be caused by cable congestion.)
Blinking red (1Hz) Fan failure, check for an inoperative fan.
Blinking red (0.25Hz) Power failure, check for a non-operational power supply.
Solid blue
Local UID has been activated. Use this function to locate
the server in a rack mount environment.
Blinking blue (300 mSEC)
Remote UID is on. Use this function to identify the
server from a remote location.