Chapter 5: Advanced Serverboard Setup
5-15
Overheat (OH)/Fan Fail/PWR Fail/
UID LED
Connect an LED cable to pins 7 and
8 of Front Control Panel to use the
Overheat/Fan Fail/Power Fail and
UID LED connections. The Red LED
on pin 7 provides warnings of over-
heat, fan failure or power failure. The
Blue LED on pin 8 works as the front
panel UID LED indicator. The Red
LED takes precedence over the Blue
LED by default. Refer to the table on
the right for pin de nitions.
HDD LED
The HDD LED connection is located
on pins 13 and 14 of JF1. This LED
is used to display all hard drive activ-
ity. See the table on the right for pin
de nitions.
NIC2 LED
Pin De nitions (JF1)
Pin# De nition
9 Vcc
10 Ground
HDD LED
Pin De nitions (JF1)
Pin# De nition
13 Vcc
14 HD Active
NIC2 LED
The LED connections for LAN2 are
on pins 9 and 10 of JF1. Attach an
LED cable to display network activ-
ity. See the table on the right for pin
de nitions.
NIC1 LED
Pin De nitions (JF1)
Pin# De nition
11 Vcc
12 Ground
NIC1 LED
The LED connections for LAN1 are
on pins 11 and 12 of JF1. Attach an
LED cable to display network activ-
ity. See the table on the right for pin
de nitions.
OH/Fan Fail Indicator
Status
State De nition
Off Normal
On Overheat
Flashing Fan Fail
Power Fail LED
The Power Fail LED connection is lo-
cated on pins 5 and 6 of JF1. See the
table on the right for pin de nitions.
PWR Fail LED
Pin De nitions (JF1)
Pin# De nition
5 3.3V
6 Signal
OH/Fan Fail/ PWR Fail/Blue_UID
LED Pin De nitions (JF1)
Pin# De nition
7 Red_LED-Cathode/OH/Fan Fail/
Power Fail5.5V.SB
8 Blue_UID LED