5-6
SUPERSERVER 6028R-WTR(T) USER'S MANUAL
3. With the lever labeled 'Close 1st'
fully retracted, gently push down
on the 'Open 1st' lever to open
the load plate. Lift the load plate
to open it completely.
WARNING!
WARNING!
Gently push
down to pop
the load plate
open.
OPEN 1st
WARNING!
Socket Keys
CPU Keys
4. Using your thumb and the index
nger, remove the 'WARNING'
plastic cap from the socket.
5. Use your thumb and index nger to hold the CPU by its edges. Align the CPU
keys, which are semi-circle cutouts, against the socket keys.
6. Once they are aligned, carefully lower the CPU straight down into the socket.
(Do not drop the CPU on the socket. Do not move the CPU horizontally or
vertically and do not rub the CPU against any pins of the socket, which may
damage the CPU or the socket.)