SUPERSERVER® 6028R-T6028R-TT SUPER®USER’S MANUAL 1.0
1-2SUPERSERVER 6028R-T/TT User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6028R-T/TT lies the X10DRi/X10DRi-T, a dual proce
7-16SUPERSERVER 6028R-T/TT User's ManualPort 0 ~ Port 5 Hot PlugSelect Enabled to enable hot-plugging support for a port specied by the user, wh
Chapter 7: BIOS7-17•Software Preserve Support sSATA Port 0~ Port 3Select Enabled to enable an sSATA port specied by the user. The options are Disabl
7-18SUPERSERVER 6028R-T/TT User's ManualsSATA RAID Option ROM/UEFI DriverSelect EFI to load the EFI driver for system boot. Select Legacy to load
Chapter 7: BIOS7-19•ME Firmware Status #2•Current State•Error CodeAltitudeThis feature indicates the altitude of the platform this machine is locat
7-20SUPERSERVER 6028R-T/TT User's ManualAbove 4G Decoding (Available if the system supports 64-bit PCI decoding)Select Enabled to decode a PCI de
Chapter 7: BIOS7-21Onboard LAN Option ROM TypeSelect Enabled to enable Option ROM support to boot the computer using a device installed on the slot sp
7-22SUPERSERVER 6028R-T/TT User's ManualDevice ModeUse this feature to congure SUART clock source settings. The options are 24MHz/13
Chapter 7: BIOS7-23is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a par
7-24SUPERSERVER 6028R-T/TT User's ManualSOL/COM2Console RedirectionSelect Enabled to use the SOL port for Console Redirection. The options are En
Chapter 7: BIOS7-25Flow ControlUse this feature to set the ow control for Console Redirection to prevent data loss caused by buffer overow. Send a &
1-3Chapter 1: Introduction1-3 Server Chassis FeaturesThe SC823T-653LPB is a 2U chassis that features six 3.5" hot-swap hard drive bays and a hig
7-26SUPERSERVER 6028R-T/TT User's Manual*If the item above set to Enabled, the following items will become available for user's conguration
Chapter 7: BIOS7-27Trusted Computing (Available when a TPM device is installed and detected by the BIOS)CongurationSecurity Device SupportIf this f
7-28SUPERSERVER 6028R-T/TT User's ManualACPI Settings WHEA SupportSelect Enabled to support the Windows Hardware Error Architecture (WHEA) plat-
Chapter 7: BIOS7-297-4 Event LogsUse this feature to congure Event Log settings.Change SMBIOS Event Log SettingsThis feature allows the user to co
7-30SUPERSERVER 6028R-T/TT User's ManualMemory Correctable Error ThresholdUse this item to enter the threshold value for correctable memory error
Chapter 7: BIOS7-317-5 IPMIUse this feature to congure Intelligent Platform Management Interface (IPMI) settings. IPMI Firmware RevisionTh
7-32SUPERSERVER 6028R-T/TT User's ManualWhen SEL is FullThis feature allows the user to determine what the BIOS should do when the sys-tem event
Chapter 7: BIOS7-33Gateway IP AddressThis item displays the Gateway IP address for this computer. This should be in decimal and in dotted quad form (i
7-34SUPERSERVER 6028R-T/TT User's Manual7-6 Security SettingsThis menu allows the user to congure the following security settings fo
Chapter 7: BIOS7-357-7 Boot SettingsUse this feature to congure Boot Settings:Boot Mode SelectUse this item to select the type of device to be used
1-4SUPERSERVER 6028R-T/TT User's ManualFigure 1-1. Chipset Block DiagramNote: This is a general block diagram. Please see Chapter 5 for details.
7-36SUPERSERVER 6028R-T/TT User's Manual•Dual Boot Order #10•Dual Boot Order #11•Dual Boot Order #12•Dual Boot Order #13•Dual Boot Order #14
Chapter 7: BIOS7-377-8 Save & ExitSelect the Save & Exit tab from the BIOS setup screen to congure the settings below.Discard
7-38SUPERSERVER 6028R-T/TT User's ManualRestore DefaultsTo set this feature, select Restore Defaults from the Exit menu and press <Enter>.
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed at each syst
A-2SUPERSERVER 6028R-T/TT User's ManualNotes
B-1Appendix B: System SpecicationsAppendix B System SpecicationsProcessorsSingle or dual Intel® E5-2600 Series (V3) Socket R3 processors in LGA 20
B-2SUPERSERVER 6028R-T/TT User's ManualChassisSC823T-653LPB (2U rackmount)Dimensions: (WxHxD) 16.8 x 3.5 x 25.6 in. (427 x 89 x 650 mm)WeightGros
B-3Appendix B: System SpecicationsDisclaimer (continued from front)The products sold by Supermicro are not intended for and will not be used in life
B-4SUPERSERVER 6028R-T/TT User's ManualNotes
1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408
1-6SUPERSERVER 6028R-T/TT User's ManualNotes
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 6028
2-2SUPERSERVER 6028R-T/TT Manual•This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets an
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
2-4SUPERSERVER 6028R-T/TT Manual2-5 Installing the System into a RackThis section provides information on installing the SuperServer 6028R-T/TT into
Chapter 2: Server Installation2-5Installing the Chassis RailsPosition one of the xed chassis rail sections you just removed along the side of the 602
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur
2-6SUPERSERVER 6028R-T/TT ManualFigure 2-3. Installing the Server into a RackInstalling the Server into the RackYou should now have rails attached to
Chapter 2: Server Installation2-7Figure 2-4. Installing the Server into a Telco RackInstalling the Server into a Telco RackIf you are installing the
2-8SUPERSERVER 6028R-T/TT ManualNotes
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the drive carri
SUPERSERVER 6028R-T/TT User's Manual3-2PowerIndicates power is being supplied to the system's power supply units. This LED should normally b
Chapter 3: System Interface3-3Information LEDThis LED will be solid blue when the UID function has been activated.When this LED ashes red, it indicat
SUPERSERVER 6028R-T/TT User's Manual3-4Notes
4-1Chapter 4: Warning Statements for AC SystemsChapter 4 Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe
4-2SUPERSERVER 6028R-T/TT User's ManualWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie benden sich in einer Si
4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta
4-4SUPERSERVER 6028R-T/TT User's ManualInstallation Instructions Warning!Read the installation instructions before connecting the system to the p
4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over
4-6SUPERSERVER 6028R-T/TT User's ManualPower Disconnection Warning 電源切断の警告システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセスするには、システムの電源はすべてのソースから切断され、電源コー
4-7Chapter 4: Warning Statements for AC Systems¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico qu
4-8SUPERSERVER 6028R-T/TT User's ManualEquipment Installation機器の設置トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可されています。 Warning!Only trained and qualie
4-9Chapter 4: Warning Statements for AC Systemsアクセス制限区域このユニットは、アクセス制限区域に設置されることを想定しています。アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いてのみ出入りが可能です。 Warning!Thi
4-10SUPERSERVER 6028R-T/TT User's ManualBattery Handling Warning!There is the danger of explosion if the battery is replaced incorrectly. Replace
4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur
4-12SUPERSERVER 6028R-T/TT User's ManualWarnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom
4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltageバックプレーンの電圧システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。修理する際には注意ください。警告当系统正在进行时,背板上有很危险的电压或能
SUPERSERVER 6028R-T/TT User's Manualivto this chapter when adding or removing processors or main memory and when reconguring the serverboard.Cha
4-14SUPERSERVER 6028R-T/TT User's ManualComply with Local and National Electrical Codes Warning!Installation of the equipment must comply with lo
4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national
4-16SUPERSERVER 6028R-T/TT User's ManualWaarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met all
4-17Chapter 4: Warning Statements for AC SystemsWarnungDie Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halt
4-18SUPERSERVER 6028R-T/TT User's Manual Warning!When installing the product, use the provided or designated connection cables, power cables and
4-19Chapter 4: Warning Statements for AC SystemsAttention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné
4-20SUPERSERVER 6028R-T/TT User's ManualNotes
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to connect the data and power cab
5-2SUPERSERVER 6028R-T/6028R-TT User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge. W
Chapter 5: Advanced Serverboard Setup5-35-3 I/O PortsThe I/O ports are located on the backplane of the motherboard. See Figure 5-2 below for the desc
vPrefaceNotes
5-4SUPERSERVER 6028R-T/6028R-TT User's Manual1. There are two levers on the LGA2011 socket. First press and release the load lever labeled &apos
Chapter 5: Advanced Serverboard Setup5-5Gently push down to pop the load plate open.3. With the lever labeled 'Close 1st' fully retracted,
5-6SUPERSERVER 6028R-T/6028R-TT User's ManualWarning: You can only install the CPU to the socket in one direction. Make sure that the CPU is pro
Chapter 5: Advanced Serverboard Setup5-71. Unplug the power cord from the power supply.2. Unscrew and remove the heatsink screws in the sequence sho
5-8SUPERSERVER 6028R-T/6028R-TT User's ManualMemory SupportThe X10DRi/X10DRi-T supports up to 1 TB of DDR4-2133/1866/1600/1333 RDIMM ECC memory (
Chapter 5: Advanced Serverboard Setup5-9Processor & Memory Module Population CongurationFor memory to work properly, follow the tables below for
5-10SUPERSERVER 6028R-T/6028R-TT User's Manual5-6 Adding PCI Add-On CardsA total of six PCI expansion (add-on) cards can be installed into the s
Chapter 5: Advanced Serverboard Setup5-11Figure 5-4. X10DRi/X10DRi-T Layout(not drawn to scale)5-7 Serverboard DetailsJPI2C1JPWR1JPWR2JOH1JL1JSD1JSD2
5-12SUPERSERVER 6028R-T/6028R-TT User's ManualX10DRi/X10DRi-T Quick ReferenceJumper Description Default SettingJBR1 BIOS Recovery Enable/Disable
Chapter 5: Advanced Serverboard Setup5-13(CPU2) Slot5 PCI-Express 3.0 x8 Slot from CPU2(CPU2) Slot6 PCI-Express 3.0 x16 Slot from CPU2(T-)SGPIO1/2/3 S
viTable of ContentsChapter 1 Introduction1-1 Overview ...
5-14SUPERSERVER 6028R-T/6028R-TT User's ManualReset ButtonThe Reset Button connection is located on pins 3 and 4 of JF1 and attaches to the reset
Chapter 5: Advanced Serverboard Setup5-15HDD LEDThe HDD LED connection is located on pins 13 and 14 of JF1. Attach a cable to Pin 14 to show HDD activ
5-16SUPERSERVER 6028R-T/6028R-TT User's ManualFan HeadersThere are eight fan headers on the serverboard (Fan 1-Fan 6, Fan A, Fan B), all of which
Chapter 5: Advanced Serverboard Setup5-17Internal SpeakerThe Internal Speaker, located at SP1, can be used to provide audible indica-tions for various
5-18SUPERSERVER 6028R-T/6028R-TT User's ManualStandby PowerThe Standby Power header is located at JSTBY1 on the serverboard. See the table on
Chapter 5: Advanced Serverboard Setup5-19Universal Serial Bus (USB)Two USB 2.0 ports (USB 0/1) and two USB 2.0/3.0 ports (USB12/13) are lo-cated on th
5-20SUPERSERVER 6028R-T/6028R-TT User's Manual5-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can b
Chapter 5: Advanced Serverboard Setup5-21CMOS ClearJBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper con
5-22SUPERSERVER 6028R-T/6028R-TT User's ManualI2C to PCI-E SlotsJumper SettingsJumper Setting Denition Pins 1-2 EnabledPins 2-3 Disabled
Chapter 5: Advanced Serverboard Setup5-235-10 Onboard IndicatorsLAN LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each port,
viiTable of ContentsReset ... 3-1Power ...
5-24SUPERSERVER 6028R-T/6028R-TT User's Manual5-11 SATA PortsSATA PortPin DenitionsPin# Denition Pin Denition1 Ground 2 TXP3
Chapter 5: Advanced Serverboard Setup5-255-12 Installing SoftwareThe Supermicro ftp site contains drivers and utilities for your system at ftp://ftp.
5-26SUPERSERVER 6028R-T/6028R-TT User's ManualSuperDoctor® 5The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-bas
Chapter 5: Advanced Serverboard Setup5-27Figure 5-7. Installing the Onboard BatteryORPlease handle used batteries carefully. Do not damage the battery
5-28SUPERSERVER 6028R-T/6028R-TT User's ManualNotes
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform main-te
6-2SUPERSERVER 6028R-T/TT User's ManualFigure 6-1. Chassis: Front and Rear ViewsIO Panel (see Figure 5-3)Low Prole PCI SlotsControl PanelSATA Dr
Chapter 6: Advanced Chassis Setup6-36-2 Control PanelThe control panel (located on the front of the chassis) must be connected to the JF1 connector o
6-4SUPERSERVER 6028R-T/TT User's ManualFigure 6-2. System Fan Removal6-4 Drive Bay Installation/RemovalAccessing the Drive BaysYou do not need
Chapter 6: Advanced Chassis Setup6-5Figure 6-3. Mounting a Drive in a CarrierCaution: Regardless of how many hard drives are installed, all drive car
viiiSUPERSERVER 6028R-T/TT User's ManualDIMM Installation ...
6-6SUPERSERVER 6028R-T/TT User's ManualFigure 6-4. Removing SATA DrivesInstalling/Removing Hot-swap SATA Drives1. Push the release button on th
Chapter 6: Advanced Chassis Setup6-7Installing a Component in the 5.25" Drive BayA single 5.25" drive bay is located in the front of the cha
6-8SUPERSERVER 6028R-T/TT User's ManualDVD-ROM Drive InstallationThe top cover of the chassis must be opened to gain full access to the DVD-ROM.
Chapter 6: Advanced Chassis Setup6-96-5 Power SupplyThe SuperServer 6028R-T/TT has a single 650 watt power supply. This power supply module has an au
6-10SUPERSERVER 6028R-T/TT User's ManualNotes
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS setup utility for the X10DRi/X10DRi-T. The ROM BIOS is stored
7-2SUPERSERVER 6028R-T/TT User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory t
Chapter 7: BIOS7-3The following Main menu items will be displayed:System Date/System Time Use this option to change the system date and time. Highligh
7-4SUPERSERVER 6028R-T/TT User's Manual7-3 Advanced Setup CongurationsUse the arrow keys to select Advanced setup and press <Enter> to a
Chapter 7: BIOS7-5Wait For 'F1' If ErrorSelect Enabled to force the system to wait until the 'F1' key is pressed if an error occur
Chapter 1 Introduction1-1 OverviewThe SuperServer 6028R-T/TT is a high-end server comprised of two main sub-systems: the SC823T-653LPB 2U server cha
7-6SUPERSERVER 6028R-T/TT User's ManualCPU CongurationNorth BridgeThis feature allows the user to congure the settings for the Intel North Br
Chapter 7: BIOS7-7The following items will be display:PCI-E Port Link StatusPCI-E Port Link MaxPCI-E Port Link SpeedPCI-E Port L0s Exit LatencyUse thi
7-8SUPERSERVER 6028R-T/TT User's ManualNo PCIe Port Active ECOUse this feature to select a workaround setting to implement the engineering-change
Chapter 7: BIOS7-9Coherency Support (Isoch)Select Enable for the Iscoh VT-d engine to pass through ATS to enhance system performance. The options are
7-10SUPERSERVER 6028R-T/TT User's ManualMemory CongurationEnforce PORSelect Enable to enforce POR restrictions on DDR4 frequency and voltage pr
Chapter 7: BIOS7-11Rank InterleavingUse this item to select a rank memory interleaving method. The options are Auto, 1-Way, 2-Way, 4-Way, and 8-Way.A7
7-12SUPERSERVER 6028R-T/TT User's Manualwrite back one cache line every 16K cycles, if there is no delay caused by internal processing. By using
Chapter 7: BIOS7-13XHCI Hand-OffThis is a work-around solution for operating systems that do not support XHCI (Ex-tensible Host Controller Interface)
7-14SUPERSERVER 6028R-T/TT User's ManualSATA CongurationWhen this submenu is selected, AMI BIOS automatically detects the presence of the SATA
Chapter 7: BIOS7-15Port 0 ~ Port 5 SATA Device TypeUse this item to specify if the SATA port specied by the user should be con-nected to