C-13
Appendix C BPN-SAS2-836EL Backplane Specications
C-12 Failover with RAID Cards and Multiple HBAs
The BPN-SAS2-836EL backplane may be congured for failover with multiple HBAs
using either RAID controllers or HBAs to achieve failover protection.
RAID Controllers: If RAID controllers are used, the failover is accomplished through
port failover on the same RAID card.
HBAs: If multiple HBAs are used to achieve failover protection and load balancing,
Linux MPIO software must be installed and correctly congured to perform
the load balancing and failover tasks.
PRI_J0
PRI_J1
PRI_J2
SEC_J0 SEC_J1
SEC_J2
SAS HBA
Port A
Expander 1
Port B
Expander 2
SAS HBA
Dual Host Bus Adapter
In a dual host bus conguration, the
backplane connects to two HBAs.
Figure C-7. Dual HBA
PRI_J0
PRI_J1
PRI_J2
SEC_J0 SEC_J1
SEC_J2
SAS HBA
Port A
Expander 1
Port B
Expander 2
SAS HBA
Dual Host Bus Adapter
Failover
If the expander or data path in Port A
fails, the system automatically switches
to Port B. This maintains a full connec-
tion to all drives.
Figure C-7. Dual HBA Failover
IMPORTANT: For RAID controllers, redundancy is achieved through port
failover. For multiple HBAs MPIO software is required to achieve failover
protection.