Chapter 5: Advanced Serverboard Setup
5-19
LAN1/2 Enable/Disable
Change the setting of jumper JPL1
and JPL2 to enable or disable the
LAN1 and LAN2 Gb Ethernet ports,
respectively. See the table on the
right for jumper settings. The default
setting is enabled
LAN1/2 Enable/Disable
Jumper Settings (JPL1/JPL2)
Jumper Setting Defi nition
Pins 1-2 Enabled
Pins 2-3 Disabled
PCI Slots to SMB
Jumpers JI
2
C1 and JI
2
C2 allow you to
connect or disconnect the PCI slots to
the System Management Bus. The de-
fault setting is pins 2-3 for both jumpers
to disable the connection. Both con-
nectors must be set the same (one is
for data and one is for clock). See the
table on right for jumper settings.
PCI Slots to SMB Jumper
Settings (JI
2
C1, JI
2
C2)
Jumper Setting Defi nition
Open Disabled
Closed Enabled
PWR Supply Failure Detect
The system can notify you in the event
of a power supply failure. This feature
is available when three power supply
units are installed in the chassis with one
acting as a backup. This jumper should
remain disabled on the 6015V-T/6015V-
TLP to prevent false alarms.
PWR Supply Failure Detect
Jumper Settings (JPWF)
Jumper Setting Defi nition
Closed Enabled
Open Disabled
Power Force On Enable/
Disable
Jumper JPF allows you to enable or
disable the Power Force-On function.
If enabled, the power will always stay
on automatically. If this function is
disabled (the normal setting), the user
needs to press the power button to
power on the system.
Power Force On
Enable/Disable
Jumper Settings (JPF)
Jumper Setting Defi nition
Open Normal
Closed Force On