Superblade Network Modules User’s Manual
26
Alarms
Clicking on the ALARMS tab brings up the RMON ALARM CONFIGURATION page
(Figure 7-20). Table 7-12 lists the parameters found on this page.
Figure 7-20. RMON Alarm Configuration Page
Table 7-12. RMON Alarm Configuration Page Parameters
Parameter Description
Index Specifies the table index.
Interval Specifies the time interval for which the alarm monitors the variable.
Variable Specifies the MIB object on which the alarm is set.
Sample Type
Specifies the method of sampling the selected variable and calculating the
value to be compared against the thresholds. The value of this object can
be Absolute or Delta.
Rising Threshold
Specifies a threshold for the sampled statistic. When the current sampled
value is greater than or equal to this threshold, and the value at the last
sampling interval was less than this threshold, an alarm is generated. It
occurs if the startup alarm is set either as a Rising Alarm or a Rising or
Falling Alarm.